Installation

1.Press the SNAP FIT of the ADAPTOR in the HOUSING to open the ADAPTOR part, and then insert all external cables into the HOUSING. Secure the HOUSING on the PIPE or MOUNT by turning it clockwise.

(Secure two components tightly, to avoid loosened HOUSING.)

PIPE OR

PIPE OR

MOUNT

MOUNT

HOUSING

HOUSING

EXTERNAL

CABLE

ADAPTOR

SNAP-FIT

2.Connect external cables to the CONNECTORS(ALARM IN, POWER, RS-485, ALARM OUT) and connect the CONNECTOR to the ADAPTOR.

Insert the cable into the FRAME SET, and close the ADAPTOR.

English

 

 

 

HOUSING

BNC JACK

 

 

 

INSULATION

 

 

 

 

POWER INPUT ALARM OUT

TUBE

 

ALARM IN

RS-485

EXTERNAL

 

 

 

 

CABLE

 

 

 

 

 

ADAPTOR

M

￿ Then, wrap the BNC JACK with the INSULATION TUBE, and use an insulation tape

 

to seal up the end of the INSULATION TUBE so that the BNC JACK does not

protrude outside of the INSULATION TUBE coating.

For more information about cable connection, refer to Connecting the adaptor cable. (page 19)