OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ALARM1
ALARM2
ALARM3
ALARM4
ALARM5
ALARM6
ALARM7
ALARM8
MOTION
AUTO SET
￿ALARM IN SET : Select the alarm sensor operation between <NO>, <NC> and <OFF>.

￿ALARM OUT SET : Set the alarm out port matched to the alarm input port.

￿AUTO SET : Sets the pattern and scan

action for the corresponding alarm input. When the alarm is generated, the

camera moves to the preset position coupled to the corresponding alarm. Presets 1 ~ 8 are coupled with alarms

1 ~ 8 inputs respectively, and the preset

9 is coupled to the motion detection. The camera stops and remains in the corresponding preset position for the defi ned <DWELL TIME>, and performs

pattern or scan action defi ned by the <AUTO SET>. Setting to <OFF> will discard with the pattern or scan action after moving to the preset position.

-PATTERN 1 ~ 3 : Defi ned pattern action-HALF1 : Patterns 1 and 2 in serial action-HALF2 : Patterns 2 and 3 in serial action-WHOLE : Patterns 1, 2 and 3 in serial action-SCAN 1 ~ 4 : Predefi ned SCAN action

MThe <ALARM1> is used as external switching signal if the <DAY/NIGHT> is set to <EXT>.

English

￿AUX OUT CONTROL : Sets whether to sustain the alarm output despite of the alarm generation or to output alarm out signal while the coupled alarm is alive.

When selected <OFF>, outputs alarm only if the alarm is generated. When selected <ON>, it always outputs alarm out signal despite of the alarm generation.

 

 

AUX OUT CONTROL

 

 

 

 

 

 

 

OUT1

 

 

 

OFF

OUT2

 

 

 

OFF

OUT3

 

 

 

OFF

English _45