5-16
3
Monitoring●Event Monitoring
You are able to set to Off/3sec/5sec/10sec/20sec/30sec/Continuous.
①Off : Event Monitoring does not operate to turn to the screen where an event
occurs.
➁3sec/ 5sec/ 10sec/ 20sec/ 30sec : For the period, the screen is seen before the
next screen appears.
➂Continuous : The Event Monitoring screen remains alive until you press the front
“Alarm” button to cancel the screen manually.
●OSG Display
①Date :
The date is displayed on the screen or not depending Date remains On or Off.
➁Time :
The time is displayed on the screen or not depending
Time
remains On or Off.
➂Title :
The title is displayed on the screen or not depending
Title
remains On or Off.
➃Status : Audio/Ptz is displayed on the screen or not depending Status remains
On or Off.
●Spot Out Channel
Spot Out channel is used to let one of two monitors monitor a channel, focusing on
it. Spot Out channel supplies two functions, continuous monitoring of only one
channel and Screen change to display all the channels one by one.
①Screen change setup ranges from CH1 to CH16.
➁Set to Screen change, Spot Out channels are displayed in turn.
➂Screen change Duration is as same as determined for Camera Configuration.
●Spot Out Event Monitor
Determines if event monitoring will be executed for Spot Out channels.
①Off : dose not event monitoring in Spot out channel.
➁3sec/ 5sec/ 10sec/ 20sec/ 30sec : Duration options on the screen before it
scrolls down.
➂Continuous : Once scrolled down, the screen remains displayed until you delete
“Alarm” LED in front manually.