SRP-370/372 Ver.2

1-4-2 Parallel & USB Interface

Switch No.

Function

ON

 

OFF

SW2-1

Select Print Density

* Refer to below Table

SW2-2

SW2-3

 

 

 

Disable

SW2-4

Historical Control

Enable

 

SW2-5

Reserved

--

by DIP

SW2-6

Interface Condition

by Memory

 

Selection

Switch

 

Switch

 

 

SW2-7

Near End Sensor Status

Disable

 

Enable

SW2-8

Printing width

2” Printing

 

3” Printing

 

DIP switch

Setting 2 Function

 

 

Default

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

SW 2-1

SW 2-2

SW 2-3

Print Density

Remark

ON

ON

ON

130%

 

OFF

ON

ON

120%

 

ON

OFF

ON

110%

 

OFF

OFF

ON

105%

 

OFF

OFF

OFF

100%

Default

ON

OFF

OFF

95%

 

OFF

ON

OFF

90%

 

ON

ON

OFF

80%

 

 

 

Select

Print Density

 

1-4-3 Auto Cutter Enable / Disable selection

 

 

 

Dip Switch Set 1

SW 5

ON

 

Auto Cutter Disabled

Application

 

Ignores Auto Cutter error for continuous printing.

Rev. 2.01

- 12 -

Page 12
Image 12