Input Connection

installation and external connection

Input Connection

Door Open Sensor

PUSH

Exit Button

Door Open Sensor

PUSH

Exit Button

GND

Input #7

GND

Input #6

GND

Input #5

GND

Input #4

GND

Input #3

GND

Input #2

GND

Input #1

- Exit Button Connection (Input #1, Input #3)

1.Connect one line of the Exit button to an input port (Door 1: Input #1, Door 2: Input #3) of the Exit button.

2.Connect the other line of the Exit button to GND (-).

- Door Sensor Connection (Input #2, Input #4)

1.Connect one line (COM) of the door open/close sensor to the input port (Door 1: Input #2, Door 2: Input #4) of the door sensor.

2.Connect the other line (NC) of the door sensor to GND (-).

 

Door Number

Exit Button

Door Open Sensor

Note

Two Door Control

1

Input #1

Input #2

 

2

Input #3

Input #4

 

 

 

 

1

Input #1

Input #2

 

Three Door Control

2

Input #8

Input #9

I/O Board

 

3

Input #10

Input #11

I/O Board

 

1

Input #1

Input #2

 

Four Door Control

2

Input #3

Input #4

 

3

Input #8

Input #9

I/O Board

 

 

4

Input #10

Input #11

I/O Board