1Preparations
1.3Before Installing the Product (Installation Guide)
To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation instructions.
Ensure that an authorized installation company installs the wall mount.
Otherwise, it may fall and cause personal injury.
Make sure to install the specified wall mount.
1.3.1Ventilation
Vertical wall mount condition
A
B
Figure 1.1 Side view
ADistance from the wall (recommended)
BAmbient Temp Measuring Point
It is strongly recommended that ambient temperature is under 30 C for
Considerable amount of heat is added to the upper units.
Internal temperature of uppermost unit is 5 ~ 10 C higher than the lowest unit. (Even there is adequate distance from the wall)
(Unit: mm)
Configuration | 1 x 1 | 2 x 2 | 3 x 3 | 4 x 4 | 5 x 5 |
|
|
|
|
|
|
A | 40 | 80 | 120 | 160 | 200 |
|
|
|
|
|
|
For more than 6 rows, auxiliary air conditioning system will be required.
1 Preparations 28