How to Change Dust Bag and Filters
CAUTION: Turn off the switch and unplug the electrical cord before servicing the cleaner. Never operate the vacuum cleaner without the dust bag in place.
NOTE: When cleaning new carpet for the first time, bag will fill quickly. Check often.
Change dust bag V when display F turns orange (can be checked with the appliance operating at maximum suction and with the nozzle raised from the fl oor). A change may be necessary even if the bag does not appear to be full. Fine dust can block the pores and reduce the suction power of the appliance.
•Remove hose and open the bag cover lid by pulling release catch G
•Remove dust bag V by pulling on the sealing tab.
•Push new dust bag into the retainer until it clicks into place. Take care when closing the dust chamber lid that the dust bag is completely inside the dust chamber border. The dust chamber lid will not close unless a dust bag has been inserted. Please do not use force!
•Change motor fi lter Z if display F is still orange after the dust bag has been changed or if the suction power is signifi cantly reduced although the dust bag has little in it.
•Replace hose.
•Press fi lter cover button W and open fi lter cover Y
•Check HEPA fi lter often and replace as necessary.
•Replace HEPA fi lter X and close lid.
Use GENUINE SANITAIRE replacement motor filter 39811, HEPA Filter, SP012 and bag SP200, package of 5.
How to Replace Brush Roll, Worn Belt or Light Bulb
NOTE : Turn off the switch and unplug the electrical cord be- fore replacing belt or bulb. Pulleys can become hot during normal use. To prevent injury, avoid touching the pulleys when servicing the drive belt.
1.Remove six screws from bottom side. Turn unit over; pull up on hood to remove.
Replace light bulb, if necessary. Use GENUINE SANITAIRE replacement bulb, 59045.
Continue to step 2 to change belt or replace brush roll. Skip to step 7 to replace hood.
2.Lift out brush roll and discard used belt.
3.Put new belt around brush roll pulley fi rst; then the motor pulley.
4.Place left end cap into the base.
5.Pull right end of brush roll to stretch belt. Secure right end cap into base.
6.Rotate brush roll at least two turns to seat belt.
7.Position hood; secure with screws.
Use GENUINE SANITAIRE replacement belt, 58065A.
F
G
V
C
Z
Y
C
X
Motor Pulley
Brush Roll
Pulley
4