Sanyo service manual Electrical Data, Electrical Characteristics KHS1822 / CH1822

Models: KHS1822 CH1822

1 17
Download 17 pages 46.49 Kb
Page 14
Image 14
7. ELECTRICAL DATA

7. ELECTRICAL DATA

Electrical Characteristics

KHS1822 / CH1822

Performance at

 

 

Indoor Unit

 

 

Outdoor Unit

 

 

Complete Unit

 

230/208V – 1ø – 60Hz

 

Fan Motor

Max. Heat

 

Fan Motor

Compressor

Heat-pump

Max. Heat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

 

Rating

A

0.40

/ 0.40

 

0.47 / 0.47

7.13

/ 7.73

8.0

/ 8.6

Conditions

W

90

/ 81

 

105 / 95

1,595

/ 1,564

1,790

/ 1,740

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating

 

Rating

A

0.40

/ 0.40

7.8

/ 7.1

 

0.47 / 0.47

7.13

/ 7.73

8.0

/ 8.6

15.8

/ 15.7

Conditions

W

90

/ 81

1,800

/ 1,470

 

105 / 95

1.595

/ 1.574

1,790

/ 1,750

3,590

/ 3,220

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Locked-Rotor Amperes

A

0.45

/ 0.40

 

0.71 / 0.64

52

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remarks:

Rating conditions are:

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling: Outside air temperature 95°F DB/75°F WB

 

 

 

 

 

 

 

Indoor unit entering air temperature 80°F DB/67°F WB

Heating: Outside air temperature 47°F DB/43°F WB

Indoor unit entering air temperature 70°F WB

9WM – 700796