INSTALLATION INSTRUCTIONS

BROIL BURNER

Burner Adjustment

1.No gas input adjustment is necessary as the infrared burner is equipped with a fixed orifice. There is no air shutter to adjust.

2.An electric ignitor is used to light the burner. DO NOT attempt to insert any object into the openings of the protective shield surrounding the ignitor coil. Do not attempt to clean this area.

3.The burner may have a hazy or fuzzy appearance when in operation. This haze may be 3/8" thick maximum and is normal for this type of burner.

UPPER OVEN FLAME CHARACTERISTIC ADJUSTMENT

The appearance of a properly adjusted gas flame is one having an inner cone of bluish-green and an outer mantle of dark blue. The length of the inner cone flame will be about 3/8" when correctly adjusted. (See Figure 9.) Flame characteristics should be clean but soft.

1.An electric ignitor is used to light the burner. DO NOT attempt to insert any object into the openings of the protective shield surrounding the ignitor coil. Do not attempt to clean this area.

2.Oven Burner Adjustment

The burner flame should be 3/8" long when the air shutter is correctly adjusted. (See Figure 9).

The air shutter is located at the left side of the upper oven burner. To adjust the air shutter loosen the lock screw. Move the air shutter to close the opening to decrease the air or enlarge the opening to increase the air. Tighten the lock screw when the adjustment is complete.

PRESSURE REGULATOR (On Range)

Remove the cap marked "Nat" and reverse it to read "LP". Be sure not to disturb or remove the spring beneath the cap. Also make sure the fiber washer is between the cap and the body of the regulator. See Figure 10 for the correction position of the cap.

Remove the cap with the screwdriver slot and replace upside down. This plug will then have the marking "LPG10". Be sure not to disturb or remove the spring beneath this plug. See Figure 11 for correct position of plug.

Figure 20

OR

Figure 21

OR

Remove the cap with the screwdriver slot. Remove the black insert marked "Nat" from the cap. (This is a tight fit in the cap.) Reverse this insert and carefully push it firmly into the hole in the cap. The marking "LP" will now be showing on the insert. Be sure the insert is pressed into the shoulder. Also, be sure not to disturb the spring in the body of the regulator.

Replace the cap in the body of the regulator and tighten. See Figure 12 for the correct position of the insert.

Figure 19

LP CONVERSION

NATURAL TO LP GAS CONVERSION

FIRE OR EXPLOSIION HAZARD

THIS UNIVERSAL RANGE IS PREADJUSTED FOR OPERATION ON "NATURAL" GAS AS SHIPPED FROM THE FACTORY. TO USE THE APPLIANCE ON LP GAS,

YOU MUST DO THE FOLLOWING: RC231002 Rev. 3

Figure 22

Remove the cap with screwdriver slot. Carefully remove the spring and washer (washer will be at bottom of spring). Reverse so that washer is at top of spring and reinstall spring and washer.

14

Page 15
Image 15
Amana RST, RSS Broil Burner, Burner Adjustment, Upper Oven Flame Characteristic Adjustment, Pressure Regulator On Range

RST, RSS specifications

The Amana RSS and RST series are designed to provide exceptional performance, efficiency, and reliability in various heating and cooling applications. These models stand out in the HVAC industry for their innovative features and technologies, making them ideal for both residential and commercial environments.

One of the main features of the Amana RSS and RST series is their advanced cooling and heating capabilities. They utilize a high-efficiency compressor that delivers powerful performance while minimizing energy consumption. This efficiency is bolstered by the inclusion of a variable-speed fan motor, which allows for precise control over airflow and temperature. As a result, these systems can operate in quieter modes, significantly reducing noise levels compared to traditional HVAC units.

The Amana RSS and RST models are equipped with a robust inverter technology that optimizes energy use by adjusting the compressor speed to match the thermal load. This constant modulation allows for better energy savings and improved indoor comfort. The systems also feature multi-stage cooling, which enhances temperature control and reduces humidity levels, ensuring a comfortable environment year-round.

In terms of technology, the Amana RSS and RST series incorporate smart controls that enable users to monitor and adjust their HVAC systems via smartphone apps or home automation systems. This connectivity provides users with real-time data on energy usage and system performance, allowing for more informed decisions about settings and schedules.

Durability is a significant characteristic of the Amana series, as they are built using high-quality materials that can withstand extreme weather conditions. Their components, including corrosion-resistant cabinets and durable coils, contribute to the longevity of the units, ensuring reliable operation for years to come.

Moreover, the Amana RSS and RST units come with a comprehensive warranty, reflecting the manufacturer's confidence in their products. Homeowners and businesses can benefit from this assurance, knowing their investment is protected.

Overall, the Amana RSS and RST series exemplify high efficiency, advanced technology, and robust construction, making them an excellent choice for those seeking dependable heating and cooling solutions. By prioritizing energy efficiency and user convenience, these models continue to set a standard in the HVAC industry.