Amana RSS, RST service manual Electronic Range Control, Operation And Service Procedures

Models: RST RSS

1 124
Download 124 pages 42.19 Kb
Page 52
Image 52
ELECTRONIC RANGE CONTROL

OPERATION AND SERVICE PROCEDURES

Electronic Range Control - ERC (Models w/One Piece Control)

TO AVOID THE RISK OF ELECTRIC SHOCK, PERSONAL INJURY OR DEATH DISCONNECT POWER BEFORE SERVICING, UNLESS TESTING REQUIRES IT.

ELECTRONIC RANGE CONTROL

V.A.C. TEST POINTS

1.E2 to E1 - 120 VAC input to ERC Circuit Board

2.E2 to E6 - 120 VAC input for K2 Broil Relay

3.E2 to E4 - 120 VAC input for K3 Bake Relay

Resolve any voltage problem before continuing.

4.Disconnect wire from E5 on Circuit Board. Program ERC for bake and select any temperature. 120 VAC should be present (E2 - E5). Reconnect wire to E5.

5.Disconnect wire from E7 on Circuit Board. Program ERC to HI Broil. 120 VAC should be constantly present (E2 - E7).

Reconnect wire to E7.

Replace Electronic Range control if Input/Output 120 VAC cannot be obtained in Steps 1 through 5 on ERC Circuit Board Test.

Figure 47

 

51

RC231002 Rev. 3

Page 52
Image 52
Amana RSS, RST service manual Electronic Range Control, Operation And Service Procedures