OHMS READINGS

OPERATION AND SERVICE PROCEDURES

Electronic Range Control (ERC) (Models w/Two Piece Control)

TO AVOID THE RISK OF ELECTRIC SHOCK, PERSONAL INJURY OR DEATH DISCONNECT POWER BEFORE SERVICING, UNLESS TESTING REQUIRES IT.

NOTE: Check each transformer terminal (J1-5, J1-6, J1-

 

TERMINALS

CIRCUIT TESTED

APPROXIMATE

7, J1-8, E1 and E2) in turn to ground terminal E3. All

OHMS READINGS

/PINS

 

readings must be infinite (OPEN).

 

J1-1 TO J1-2

BAKE RELAY COIL

560 OHMS

J1-1 TO J1-3

BROIL RELAY COIL

560 OHMS

J1-5 TO J1-6

TRANSFORMER SECONDARY WINDING

5-7 OHMS

J1-7 TO J1-8

TRANSFORMER SECONDARY WINDING

2-4 OHMS

E1 TO E2

TRANSFORMER PRIMARY WINDING

120-150 OHMS

E4 TO E5

BROIL RELAY CONTACT

INFINITE OHMS (OPEN)

E6 TO E7

BAKE RELAY CONTACT

INFINITE OHMS (OPEN)

 

 

 