Amana RSS, RST BURNER CAPS Models with Cast Sealed Burners, To Check Burner-Burner Caps

Models: RST RSS

1 124
Download 124 pages 42.19 Kb
Page 78
Image 78
BURNER CAPS

OPERATION AND SERVICE PROCEDURES

3.Spark gap should be checked and, if necessary, adjust to dimension shown.

4.Clean electrode and grounding rivet with fine file to assure ground path for spark.

5.Be certain all slots and holes are clear of cleansing powder, grease, etc.

BURNER CAPS

Models with Cast Sealed Burners

TO CHECK BURNER-BURNER CAPS:

1.

Turn off power to unit.

 

2.

Remove cast cap from base.

 

3.

Be certain the underside of burner cap is clear of

Figure 78

 

metal shavings, grease, cleansing powder, etc.

 

 

4.Be certain top side of burner base is clear of metal shavings, grease, cleansing powder, etc.

5.Spark gap should be checked and, if necessary, adjusted to dimension shown.

6.Spark should be visible between electrode wire tip and bottom side of burner cap. Spark jump to burner base (not between spark gap) could be due to cracked/ broken ceramic portion of electrode assembly which requires replacement.

Figure 79