Electronic Range Control (ERC) (Models w/ Two Piece Control)

TO AVOID THE RISK OF ELECTRIC SHOCK, PERSONAL INJURY OR DEATH DISCONNECT POWER BEFORE SERVICING, UNLESS TESTING REQUIRES IT.

When the ERC initiates the bake operations, a volt- age reading of approximately 24 VDC should be indicated. If no voltage is indicated, check for the input supply voltage at pins J1-3 and J1-4 (Step 3).

5.To check the broil relay drive voltage, insert your DC voltmeter leads into the J1 connector at pins J1-8 and J1-5, and program the ERC for a broil operation. When the ERC initiates the broil operation, a voltage reading of approximately 24 VDC should be indi- cated. If no voltage is indicated, check for the input supply voltage at pins J1-3 and J1-4 (Step 3).