Amana RSS service manual Operation And Service Procedures, Models RST359, 361, 362, 365

Models: RST RSS

1 124
Download 124 pages 42.19 Kb
Page 60
Image 60
Manual background

OPERATION AND SERVICE PROCEDURES

(Models RST359, 361, 362, 365, 399)

TO AVOID THE RISK OF ELECTRIC SHOCK, PERSONAL INJURY OR DEATH DISCONNECT POWER BEFORE SERVICING, UNLESS TESTING REQUIRES IT.

CLOCK TIMER

FUNCTION

11-12

13-14

 

 

 

MANUAL

0

0

 

 

 

DELAY IN AUTO

0

0

 

 

 

COOKING IN AUTO

X

X

 

 

 

AUTO COMPLETE

0

0

 

 

 

O = OPEN X = CLOSED

 

 

 

 

 

Timer Switching Schedule

5.Push self-clean button in. The following should take place immediately - three (3) hours (3:00) should appear in the display, the letter "C" should appear on the left side of the display, the oven-on symbol should also appear on the left and both switches should be closed. Manually, with "TIME SET" control, turn the digital display down to one (1) minute. Allow the timer to countdown to 0:00. Display should return to time of day and the switches open. NOTE: A slight "click" can be heard whenever the relay switches open or close.

59

RC231002 Rev. 3

Page 60
Image 60
Amana RSS service manual Operation And Service Procedures, Models RST359, 361, 362, 365