Amana RSS, RST Trouble Shooting Guide, Electronic Range Control ERC Models w/Two Piece Control

Models: RST RSS

1 124
Download 124 pages 42.19 Kb
Page 42
Image 42
TROUBLE SHOOTING GUIDE

TROUBLE SHOOTING GUIDE

Electronic Range Control (ERC) (Models w/Two Piece Control)

TO AVOID THE RISK OF ELECTRIC SHOCK, PERSONAL INJURY OR DEATH DISCONNECT POWER BEFORE SERVICING, UNLESS TESTING REQUIRES IT.

 

PROBLEMS

 

POSSIBLE CAUSE

 

CORRECTION

 

 

 

 

 

 

 

 

A.

Display flashes the

1.

Power failure.

1.

This is a normal condition wh

 

Time-of-Day

 

 

 

Press the "CLOCK" button a

 

 

2.

Intermittent connection

 

Tighten loose connections o

 

 

 

between E.R.C. and

 

wiring.

 

 

 

relay/power supply board.

 

 

 

 

 

3.

Defective E.R.C.

 

Replace E.R.C.

 

 

 

 

 

 

 

B.

No Display - E.R.C.

1.

No power to range.

1.

Check house fuse or circuit b

 

totally inoperative

 

 

 

wall outlet or junction box.

 

 

2.

No voltage to relay/power

2.

Check for 120 VAC at relay/

 

 

 

supply circuit board.

 

terminals E1 and E2. If no v

 

 

 

 

 

range wiring. If voltage is ind

 

 

3.

No seconday output drive

3.

Check for secondary drive vo

 

 

 

voltage from relay/power

 

VAC) at relay board pins J1-

 

 

 

supply circuit board.

 

indicated and Steps 1 and 2

 

 

 

 

 

relay/power supply circuit bo

 

 

 

 

 

proceed to Step 4.

 

 

4.

No input drive voltage to

4.

Check for input drive voltage

 

 

 

E.R.C.

 

and J1-4 (approximately 20.3

 

 

 

 

 

indicated, check wiring betw

 

 

 

 

 

supply circuit board. If voltag

 

 

 

 

 

Step 5.

 

 

5.

Defective E.R.C.

 

If Steps 1-4 above check go

 

 

 

 

 

 

 

C.

No Display - Range still

1.

No Secondary output

1.

Check for secondary output

 

operates in bake, broil,

 

filament voltage from

 

relay/power supply circuit bo

 

clean functions.

 

relay/power supply circuit

 

(approximately 3.2 VAC). If n

 

 

 

board.

 

replace relay board. If voltag

 

 

 

 

 

Step 2.

 

 

2.

No filament voltage to

2.

Check for filament voltage (a

 

 

 

E.R.C.

 

E.R.C. J1-1 and J2-2. If no v

 

 

 

 

 

wiring between E.R.C. and r

 

 

 

 

 

is indicated, proceed to Step

 

 

3.

Defective E.R.C.

3.

If Steps 1 and 2 check good

 

 

 

 

 

 

 

41

RC231002 Rev. 3

Page 42
Image 42
Amana RSS, RST service manual Trouble Shooting Guide, Electronic Range Control ERC Models w/Two Piece Control