OPERATION AND SERVICE PROCEDURES

(SLIDE IN MODELS)

TO AVOID THE RISK OF ELECTRIC SHOCK, PERSONAL INJURY OR DEATH DISCONNECT POWER BEFORE SERVICING, UNLESS TESTING REQUIRES IT.

Figure 57 - Clock/Timer P.C. Board

5.Set the Cook/Clean time for one (1) minute by press- ing the "COOK/CLEAN TIME" button ("0:00" will be displayed) and then pressing the "UP" button one time ("0:01" should be displayed). After a short delay the TB4 - TB5 contact should close (zero ohms), "AUTO" and the oven indicator symbol should appear on the left and center of the display, and the Time-of- Day will appear on the digital display. When the one

(1) minute Cook/Clean time elapses, the TB4 - TB5 contact should open (infinite ohms), an alarm will sound for approximately ten (10) seconds and the oven indicator symbol in the center of the display will turn off. "AUTO" will continue to blink ON and OFF to indicate that the Clock/Timer was programmed for a timed operation. Press the "CANCEL/CLOCK" button to turn off the blinking "AUTO" display.

6.Press the "STOP TIME" button and enter the stop time for two (2) minutes past the time of day. EX- AMPLE: Set the Time-of-Day to 12:00.

Press the "STOP TIME" button (the display will continue to show the Time-of-Day), then press the "UP" button until "12:02" is displayed.

After a short delay, contact TB4 - TB5 should close (continuity) and the display will show the Time-of-Day

along with the oven indicator in the center of the display and "AUTO" on the left of the display.

When the stop time is reached, the TB4 - TB5 contact should open (infinite ohms), the oven indicator in the center of the display turns off, and an alarm will sound approximately ten (10) seconds. "AUTO" will con- tinue to flash ON and OFF to designate that the Clock/ Timer was programmed for a timing function. Press the "CANCEL/CLOCK" button to turn off the flashing "AUTO" display.

7.Connnect the ohmmeter leads to terminals TB6 and TB7 and repeat Steps 4 - 6 to test the other K1 relay contact.

CLOCK P.C. BOARD VOLTAGE TESTS

Extreme caution must be taken when performing any live voltage tests to avoid the possibility of electrical shock or damage to the range components and/or testing equip- ment.

1.Shut off power to the range and disconnect the wire leads from the P.C. board terminals L1 (TB1) and N (TB2) to check the input voltage. Using a voltmeter

27

RC231002 Rev. 3

Page 28
Image 28
Amana RSS, RST service manual Clock P.C. Board Voltage Tests

RST, RSS specifications

The Amana RSS and RST series are designed to provide exceptional performance, efficiency, and reliability in various heating and cooling applications. These models stand out in the HVAC industry for their innovative features and technologies, making them ideal for both residential and commercial environments.

One of the main features of the Amana RSS and RST series is their advanced cooling and heating capabilities. They utilize a high-efficiency compressor that delivers powerful performance while minimizing energy consumption. This efficiency is bolstered by the inclusion of a variable-speed fan motor, which allows for precise control over airflow and temperature. As a result, these systems can operate in quieter modes, significantly reducing noise levels compared to traditional HVAC units.

The Amana RSS and RST models are equipped with a robust inverter technology that optimizes energy use by adjusting the compressor speed to match the thermal load. This constant modulation allows for better energy savings and improved indoor comfort. The systems also feature multi-stage cooling, which enhances temperature control and reduces humidity levels, ensuring a comfortable environment year-round.

In terms of technology, the Amana RSS and RST series incorporate smart controls that enable users to monitor and adjust their HVAC systems via smartphone apps or home automation systems. This connectivity provides users with real-time data on energy usage and system performance, allowing for more informed decisions about settings and schedules.

Durability is a significant characteristic of the Amana series, as they are built using high-quality materials that can withstand extreme weather conditions. Their components, including corrosion-resistant cabinets and durable coils, contribute to the longevity of the units, ensuring reliable operation for years to come.

Moreover, the Amana RSS and RST units come with a comprehensive warranty, reflecting the manufacturer's confidence in their products. Homeowners and businesses can benefit from this assurance, knowing their investment is protected.

Overall, the Amana RSS and RST series exemplify high efficiency, advanced technology, and robust construction, making them an excellent choice for those seeking dependable heating and cooling solutions. By prioritizing energy efficiency and user convenience, these models continue to set a standard in the HVAC industry.