INSTALLATION INSTRUCTIONS

BURNER ADJUSTMENT

No gas input adjustment is necessary as the burner are equipped with fixed orifices. There are no shutters to adjust. NOTE: On LP gas a slight yellow tip will be visible on top burner flames, but will not affect burner perfor- mance.

OR

TOP BURNER ADJUSTMENT (Above Serial Number F0430127550)

TO CONVERT

Lift off four (4) burner caps. (See Figure 27.) Remove one

(1)screw at each burner body. Pull each burner body upwards and disconnect the ignition wire at the electrode. Mark wires for identification on reassembly. Remove one

(1)flat headed screw at each burner and lift off main top.

Remove plenum box covers (when equipped). Remove two (2) screws from each venturi mounting bracket and remove venturi assemblies.

Turn the orifice hoods onto the pins. The orifices should be turned snug onto the pins careful not to drive pin into the valve or distort the hole through the center of the pin. Reinstall the burner bodies and caps.

The air shutters should be adjusted for a proper flame. Adjust the air shutter so that the flame has an inner cone of bluish-green and an outer mantle of dark blue. The flame should be soft in character. To adjust the air shutter, loosen the lock screw. Move the air shutter to close the opening to decrease the air or enlarge the opening for more air. Tighten the lock screw when the adjustment is com- plete. Reinstall the plenum box covers, main top and main top burners in reverse order of removal. NOTE: On LP gas a slight yellow tip will be visible on top burner flames, but will not affect burner performance.

Figure 27

 

MODELS WITH CAST BURNERS

 

TO CONVERT

 

Lift off four (4) burner caps. (See Figure 28.) Remove one

 

(1) screw at each burner body. Pull each burner body

 

upwards and disconnect the ignition wire at the electrode.

16

RC231002 Rev. 3

Remove one (1) flat headed screw at each burner and lift off main top.

Remove plenum box covers. Remove two (2) screws from each venturi mounting bracket and remove venturi assem- blies.

Turn the orifice hoods onto the pins. The orifice should be turned snug onto the pins careful not to drive pin into the valve or distort the hole through the center of the pin. Reinstall the burner bodies and caps.

The air shutters should be adjusted for a proper flame. Adjust the air shutter so that the flame has an inner cone of bluish-green and an outer mantle of dark blue. The flame should be soft in character. To adjust the air shutter, loosen the lock screw. Move the air shutter to close the opening to decrease the air or enlarge the opening for more air. Tighten the lock screw when the adjustment is com- plete. Reinstall the plenum box covers, main top and main top burners in reverse order of removal. NOTE: On LP gas a slight yellow tip will be visible on top burner flames, but will not affect burner performance.

Figure 28

OVEN BURNER (Upper and Lower Oven) (RST)

ORIFICES

Turn down the orifice hood onto the pin. The orifice should be turned snug onto the pin being careful not to drive pin into the valve or to distort the hole through the center of the pin.

LOWER OVEN FLAME CHARACTERISTIC ADJUSTMENT

The appearance of a properly adjusted oven burner flame is a bluish-green inner cone and a dark blue mantle. The flame characteristics should be clean and soft with no yellow tips. Blowing or lifting of the flame should not occur. The burner flame should be 1/2" long when the air shutter is correctly adjusted. (See Figure 18.)

An electric ignitor is used to light the burner. DO NOT attempt to insert any object into the openings of the protective shield surrounding the ignitor coil. Do not attempt to clean this area.

Page 17
Image 17
Amana RST, RSS service manual TOP Burner Adjustment Above Serial Number F0430127550, Models with Cast Burners To Convert

RST, RSS specifications

The Amana RSS and RST series are designed to provide exceptional performance, efficiency, and reliability in various heating and cooling applications. These models stand out in the HVAC industry for their innovative features and technologies, making them ideal for both residential and commercial environments.

One of the main features of the Amana RSS and RST series is their advanced cooling and heating capabilities. They utilize a high-efficiency compressor that delivers powerful performance while minimizing energy consumption. This efficiency is bolstered by the inclusion of a variable-speed fan motor, which allows for precise control over airflow and temperature. As a result, these systems can operate in quieter modes, significantly reducing noise levels compared to traditional HVAC units.

The Amana RSS and RST models are equipped with a robust inverter technology that optimizes energy use by adjusting the compressor speed to match the thermal load. This constant modulation allows for better energy savings and improved indoor comfort. The systems also feature multi-stage cooling, which enhances temperature control and reduces humidity levels, ensuring a comfortable environment year-round.

In terms of technology, the Amana RSS and RST series incorporate smart controls that enable users to monitor and adjust their HVAC systems via smartphone apps or home automation systems. This connectivity provides users with real-time data on energy usage and system performance, allowing for more informed decisions about settings and schedules.

Durability is a significant characteristic of the Amana series, as they are built using high-quality materials that can withstand extreme weather conditions. Their components, including corrosion-resistant cabinets and durable coils, contribute to the longevity of the units, ensuring reliable operation for years to come.

Moreover, the Amana RSS and RST units come with a comprehensive warranty, reflecting the manufacturer's confidence in their products. Homeowners and businesses can benefit from this assurance, knowing their investment is protected.

Overall, the Amana RSS and RST series exemplify high efficiency, advanced technology, and robust construction, making them an excellent choice for those seeking dependable heating and cooling solutions. By prioritizing energy efficiency and user convenience, these models continue to set a standard in the HVAC industry.