BEFORE SERVICING, UNLESS TESTING REQUIRES

OPERATION AND SERVICE PROCEDURES

FIRE OR EXPLOSION

TO AVOID THE RISK OF ELECTRICAL SHOCK,

PERSONAL INJURY OR DEATH DISCONNECT POWER

BEFORE SERVICING, UNLESS TESTING REQUIRES

IT.

SELECTOR SWITCH

Selector Switch Circuit

The selector switch is a two (2) position switch used for "MANUAL" or "AUTOMATIC" bake operation. The selec- tor switch contacts can be checked for continuity by using a continuity tester or an ohmmeter set to low ohms range and following the selector switch contact chart. Power to the oven must be turned off and the selector switch wiring removed when checking the contacts for continuity. Ac- cess to the selector switch contacts can be made by removing the control panel. NOTE: The selector switch is not found on models with the ERC.

SELECTOR SWITCH CONTACTS

POSITION

B to 3

B to 4

 

 

 

MANUAL

X

0

 

 

 

AUTO

0

X

 

 

 

O = OPEN X = CLOSED

 

 

 

 

 

71

OVEN THERMOSTAT (Not Used On Models With ERC)

The oven thermostat maintains the correct oven tempera- tures in the bake, broil, and self-clean operations. The thermostat is located under the control panel.

In manual and timed bake operations, thermostat contacts C-BA and 1-2 close completing the bake circuit through the clock in a timed bake operation, the selector switch, bake ignitor, and bake gas valve to neutral. Thermostat con- tacts 1-2 are the cycling contacts that maintain the correct oven temperatures.

In a boil operation, thermostat contacts C-BR and 1-2 close completing the broil circuit through the broil ignitor, and

broil gas valve to neutral. Thermostat contacts 1-2 are the cycling contacts that maintain correct broiling tempera- tures.

In the self-clean function with oven temperatures below approximately 700°F., thermostat contacts COM-NO, 7-9 and 1-2 close completing the clean circuit through the latch switch, the broil ignitor, and broil gas valve to neutral.

After the oven temperature reaches approximately 700°F., thermostat contacts COM-NO open and COM-NC close now completing the circuit through the latch switch, selec- tor switch, timer contacts, bake ignitor, and bake gas valve to neutral. Contacts 1-2 cycle to maintain correct self- cleaning temperatures.

The thermostat contacts can be checked for continuity by using a continuity tester or an ohmmeter set to the low

RC231002 Rev. 3

Page 72
Image 72
Amana RSS, RST Before Servicing, Unless Testing Requires It Selector Switch, OVEN THERMOSTAT Not Used On Models With ERC