IMPORTANT!

Please Read Before Starting

This air conditioning system meets strict safety and operating standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently.

For safe installation and trouble-free operation, you must:

Carefully read this instruction booklet before beginning

Follow each installation or repair step exactly as shown

Observe all local, state, and national electrical codes

Pay close attention to all warning and caution notices given in this manual

When Transporting

Be careful when picking up and moving the indoor and out- door units. Get a partner to help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin aluminum fins on the air conditioner can cut your fingers.

When Installing…

…In a Ceiling or Wall

Make sure the ceiling/wall is strong enough to hold the unit’s weight. It may be necessary to construct a strong wood or metal frame to provide added support.

…In a Room

Properly insulate any tubing run inside a room to prevent “sweating” that can cause dripping and water damage to walls and floors.

WARNING:

CAUTION:

This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death.

This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage.

…In Moist or Uneven Locations

Use a raised concrete pad or concrete blocks to provide a solid, level foundation for the outdoor unit. This prevents water damage and abnormal vibration.

…In an Area with High Winds

Securely anchor the outdoor unit down with bolts and a metal frame. Provide a suitable air baffle.

If Necessary, Get Help

These instructions are all you need for most installation sites and maintenance conditions. If you require help for a special problem, contact our sales/service outlet or your certified dealer for additional instructions.

In Case of Improper Installation

The manufacturer shall in no way be responsible for improper installation or maintenance service, including failure to follow the instructions in this document.

SPECIAL PRECAUTIONS

When Wiring

ELECTRICAL SHOCK CAN CAUSE SEVERE PER- SONAL INJURY OR DEATH. ONLY A QUALIFIED, EXPERIENCED ELECTRICIAN SHOULD ATTEMPT TO WIRE THIS SYSTEM.

Do not supply power to the unit until all wiring and tub- ing are completed or reconnected and checked.

Highly dangerous electrical voltages are used in this sys- tem. Carefully refer to the wiring diagram and these instructions when wiring. Improper connections and inad- equate grounding can cause accidental injury or death.

Ground the unit following local electrical codes.

Connect all wiring tightly. Loose wiring may cause over- heating at connection points and a possible fire hazard.

…In a Snowy Area (for Heat Pump-type Systems)

Install the outdoor unit on a raised platform that is higher than drifting snow. Provide snow vents.

When Connecting Refrigerant Tubing

Keep all tubing runs as short as possible.

Use the flare method for connecting tubing.

Apply refrigerant lubricant to the matching surfaces of the flare and union tubes before connecting them, then tighten the nut with a torque wrench for a leak-free connection.

Check carefully for leaks before starting the test run.

NOTE:

Depending on the system type, liquid and gas lines may be either narrow or wide. Therefore, to avoid confusion the refrigerant tubing for your particular model is specified as either “narrow” or “wide” rather than as “liquid” or “gas.”

When Servicing

Turn the power OFF at the main power box (mains) before opening the unit to check or repair electrical parts and wiring.

Keep your fingers and clothing away from any moving parts.

Clean up the site after you finish, remembering to check that no metal scraps or bits of wiring have been left inside the unit being serviced.

iiiWM – 700796

Page 4
Image 4
Sanyo CH1822, KHS1822 service manual Please Read Before Starting, For safe installation and trouble-free operation, you must

KHS1822, CH1822 specifications

The Sanyo CH1822 is a versatile and reliable air conditioning unit that offers a blend of advanced technology and efficient performance. Renowned for its energy efficiency, the CH1822 is designed to provide optimal cooling and heating solutions for residential and small commercial spaces. Its state-of-the-art features make it a popular choice among consumers looking for comfort and reliability.

One of the standout characteristics of the Sanyo CH1822 is its advanced inverter technology. This feature allows the unit to adjust its cooling and heating capacity according to the specific needs of the environment. By continuously varying the compressor speed, the inverter technology not only maintains a stable temperature but also significantly reduces energy consumption, making the CH1822 an eco-friendly option.

The CH1822 is equipped with a powerful cooling capacity, capable of delivering swift and effective temperature regulation. It can cool or heat areas quickly, ensuring that users achieve their desired comfort levels in record time. The unit’s high SEER (Seasonal Energy Efficiency Ratio) rating underscores its efficiency, indicating substantial savings on energy bills over time.

Another notable feature is the various modes of operation available on the Sanyo CH1822. It includes modes such as cooling, heating, dehumidification, and fan-only, providing flexibility based on user preference and seasonal needs. The dehumidification mode is particularly useful during humid months, as it allows the unit to remove excess moisture from the air, improving indoor air quality.

Additionally, the CH1822 comes with a user-friendly remote control that enables easy adjustments from a distance. The remote control features a clear display for convenient monitoring and control of settings, including temperature, fan speed, and operational modes.

The design of the Sanyo CH1822 is another aspect that consumers appreciate. It features a sleek, modern aesthetic that easily integrates with a variety of interior styles. Its compact form factor also ensures it can fit into smaller spaces without compromising on performance.

In summary, the Sanyo CH1822 air conditioning unit combines advanced inverter technology with a range of user-friendly features, making it an ideal choice for those seeking an efficient and effective climate control solution. Whether for keeping cool in hot weather or providing warmth during the cold months, the CH1822 delivers reliable performance and comfort year-round. Its energy-saving capabilities, multiple operational modes, and stylish design make it a standout option in the market.