Loose wiring may cause the

WARNING

Loose wiring may cause the

terminal to overheat or result

 

 

 

in unit malfunction. A fire

 

hazard may also exist. There-

 

fore, be sure all wiring is

 

tightly connected.

When connecting each power wire to the corresponding terminal, follow the instructions “How to connect wiring to the terminal” and fasten the wire securely tight with the fixing screw of the terminal plate.

How to connect wiring to the terminal

a) For Indoor Unit

(1)Cut the wire end with a cutting pliers, then strip the insulation to expose the wire about 9/32" (7 mm). See the label (Fig. 28) near the terminal plate.

(2)Using a screwdriver, loosen the terminal screw on the terminal plate.

(3)Insert the wire and tighten the terminal screw com- pletely using a screwdriver.

b) For Outdoor Unit

For solid core wiring (or F-cable)

(1)Cut the wire end with a cutting pliers, then strip the insulation to expose the solid wire about 15/16" (25 mm). (Fig. 29)

(2)Using a screwdriver, remove the terminal screw(s) on the terminal plate.

(3)Using the pliers, bend the solid wire to form a loop suitable for the terminal screw.

(4)Shape the loop wire properly, place it on the termi- nal plate and fix it securely with the removed termi- nal screw using a screwdriver.

For stranded wiring

(1)

Cut the wire end with a cutting pliers, then strip the

 

insulation to expose the stranded wiring about 3/8"

 

(10 mm) and tightly twist the wire ends. (Figs. 30

 

and 31)

(2)

Using a screwdriver, remove the terminal screw(s)

9/32"

STRIP

(7 mm) (ACTUAL

SIZE)

SIZE

 

Fig. 28

mm)

Solid wire

 

Strip 15/16" (25

Loop

Insulation

 

 

Fig. 29

mm)

Stranded wire

Ring

(10

connector

Strip 3/8"

 

Fig. 30

Twist wire ends

Fig. 31

 

on the terminal plate.

(3)

Using a ring connector fastener or pliers, securely

 

clamp each stripped wire end with a ring connector.

 

(Fig. 30)

(4)

Place the ring connector wire, and replace and

 

tighten the removed terminal screw using a screw-

 

driver. (Fig. 32)

Special washer

Wire

Screw

Ring connector Terminal plate

Wire

Fig. 32

Screw and special washer

Ring connector