4. How to Install the Outdoor Unit

First refer to Section 2. Installation Site Selection.

4-1. Wiring Instructions for the Outdoor Unit

Regulations on wire size differ from locality to locality. For field wiring requirements, please refer to your local elec- trical codes. Make sure that the installation fully complies with all local and national regulations.

(1)Remove access panel “C”. (Fig. 46)

(2)Connect the inter-unit and power supply line accord- ing to the drawing on the panel side.

(3)Be sure to size each wire allowing approx. 4"

(10 cm) longer than the required length for wiring. Store excess wiring inside the cabinet.

(4)When connections are completed, check that all connections are correct as shown in the wiring sys- tem diagram on panel side.

(5)Be sure to ground the unit according to your local codes.

Lock nut

Cabinet

Terminal block

Conduit plate

Access panel C

Plug

Inter unit

Power supply

 

(Conduit)

(Conduit)

Fig. 46

17