■How to test run the air conditioner

03-242.Sanyo.85464359404000 8/21/03 9:17 AM Page 4

How to test run the air conditioner

1.Switch on the power source.

2.Press the ON/OFF button on the remote control unit once.

3.Set the operation selector switch of the indoor unit to the TEST position. This starts the fan, producing uncooled forced air. (Fig. 7)

4.After 3 minutes, the system shifts into cooling oper- ation, and cool air will start to be felt. Cooling oper- ation with the switch at the TEST position is unaf- fected by the room temperature.

5.After stopping the test run, turn the operation selec- tor switch of the indoor unit to the OFF position once, then move to ON position. (Fig. 7)

6.Press the ON/OFF button on the remote control unit to stop the air conditioner.

NOTE

If the unit does not operate and the OPERATION lamp on the unit is blinking after going through the proce- dure, check the wiring between the units.

INDOOR UNIT

ON

OFF

TEST

Operation selector

OPERATION lamp TIMER lamp Remote control

 

receiver

OPERATION

TIMER

Fig. 7