ECOi 2 Way Heat Pump VRF Inverter Systems

HP

 

 

 

8

10

12

14

16

18

20

22

24

26

28

30

32

34

 

36

38

40

42

44

46

48

 

 

 

 

 

 

C0705DXHN8

C0905DXHN8

C1155DXHN8

C1305DXHN8

C1405DXHN8

10 C0905DXHN8

10 C0905DXHN8

12 C1155DXHN8

14 C1305DXHN8

 

16 C1405DXHN8

16 C1405DXHN8

16 C1405DXHN8

16 C1405DXHN8

14 C1305DXHN8

16 C1405DXHN8

16 C1405DXHN8

16 C1405DXHN8

16 C1405DXHN8

16 C1405DXHN8

16 C1405DXHN8

16 C1405DXHN8

Model

 

 

 

 

 

 

 

 

8 C0705DXHN8

10 C0905DXHN8

10 C0905DXHN8

10 C0905DXHN8

 

10 C0905DXHN8

12 C1155DXHN8

14 C1305DXHN8

16 C1405DXHN8

10 C0905DXHN8

10 C0905DXHN8

12 C1155DXHN8

14 C1305DXHN8

16 C1405DXHN8

16 C1405DXHN8

16 C1405DXHN8

16 C1405DXHN8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 C0905DXHN8

10 C0905DXHN8

10 C0905DXHN8

10 C0905DXHN8

10 C0905DXHN8

12 C1155DXHN8

14 C1305DXHN8

16 C1405DXHN8

Power supply

 

 

 

 

 

 

 

 

 

 

 

 

380/400/415V - 3 phase/50,60Hz

 

 

 

 

 

 

 

 

 

 

 

Cooling capacity

 

kW

 

22.40

28.00

33.50

40.00

45.00

50.40

56.00

61.50

68.00

 

73.00

78.50

85.00

90.00

96.00

 

101.00

107.00

113.00

118.00

124.00

130.00

135.00

Heating capacity

 

kW

 

25.00

31.50

37.50

45.00

50.00

56.50

63.00

69.00

76.50

 

81.50

87.50

95.00

100.00

108.00

 

113.00

119.00

127.00

132.00

138.00

145.00

150.00

EER Cooling

 

kW

 

3.74

3.54

3.50

3.45

3.38

3.63

3.54

3.51

3.49

 

3.44

3.43

3.41

3.38

3.50

 

3.47

3.47

3.45

3.42

3.43

3.40

3.38

COP Heating

 

kW

 

4.05

4.06

3.91

3.91

3.79

4.06

4.06

3.97

3.96

 

3.88

3.84

3.85

3.79

4.00

 

3.94

3.89

3.91

3.86

3.83

3.83

3.79

 

 

 

 

Running

A

10.1/9.6/9.3

13.3/12.7/12.2

16.2/15.4/14.8

20.0/19.0/18.3

23.0/21.8/21.0

23.4/22.3/21.5

26.6/25.4/24.4

29.5/28.1/27

33.3/31.7/30.5

 

36.3/34.5/33.2

39.2/37.2/35.8

43.0/40.8/39.3

46.0/43.6/42.0

46.6/44.4/42.7

 

49.6/47.2/45.4

52.5/49.9/48.0

56.3/53.5/51.5

59.3/56.3/54.2

62.2/59.0/56.8

66.0/62.6/60.3

69.0/65.4/63.0

 

Cooling

amperes

 

 

 

Power

kW

5.99

7.90

9.58

11.60

13.30

13.90

15.80

17.50

19.50

 

21.20

22.90

24.90

26.60

27.40

 

29.10

30.80

32.80

34.50

36.20

38.20

39.90

 

 

 

 

 

 

Electric

 

 

 

input

 

 

rating

 

 

 

Running

A

10.4/9.9/9.5

13.1/12.4/12.0

16.2/15.4/14.8

19.9/18.9/18.2

22.8/21.6/20.9

23.5/22.3/21.5

26.2/24.8/24.0

29.3/27.8/26.8

33.0/31.3/30.2

 

35.9/34.0/32.9

39.0/37.0/35.7

42.7/40.5/39.1

45.6/43.2/41.8

46.1/43.7/42.2

 

49.0/46.4/44.9

52.1/49.4/47.7

55.8/52.9/51.1

58.7/55.6/53.8

61.8/58.6/56.6

65.5/62.1/60.0

68.4/64.8/62.7

 

Heating

amperes

 

 

 

Power

kW

6.17

7.75

9.60

11.50

13.20

13.90

15.50

17.70

20.70

 

22.60

23.10

26.10

28.00

29.30

 

31.20

30.60

34.70

34.20

37.10

37.90

42.00

 

 

 

 

 

 

 

 

 

 

input

 

 

Recommended fuse sizes (motor rated)

 

32

 

40

 

32x2

 

1x40

 

1x40

2x40

 

 

2x32

 

 

1x32

 

3x40

 

 

 

 

1x32

 

1x32

 

 

1x40

 

 

2x40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions 

(H/W/D)

mm

 

 

1887×890×890 (+60)

 

 

1887×1880×890 (+60)

 

 

 

1887×1880×890 (+60)

 

 

 

 

 

1887×2870×890 (+60)

 

 

 

Net weight

 

kg

 

245

295

345

540

590

640

 

640

690

 

 

929

 

 

985

 

1035

Air circulation

 

m3/min

 

150

160

180

200

220

160+150

160+160

180+160

200+160

 

220+160

220+180

220+220

200+160+160

 

220+160+160

220+180+160

220+200+160

220+220+160

220+220+180

220+220+200

220+220+220

Piping

 

Gas

 

 

3/4 (19.05)

7/8 (22.22)

 

 

 

1 1/8 (28.58)

 

 

 

 

 

 

1 3/8 (34.92)

 

 

 

 

 

 

1 5/8 (41.27)

 

 

 

 

Liquid

Inches (mm)

3/8 (9.52)

 

1/2 (12.7)

 

 

5/8 (15.88)

 

 

 

 

 

 

 

 

3/4 (19.05)

 

 

 

 

 

connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Balance

 

 

 

 

 

 

 

 

 

 

 

1/4 (6.35)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operating sound normal

 

 

54.5

55.0

56.0

60.0

61.0

58.0

58.5

61.5

 

62.0

62.5

63.5

64.0

62.5

 

63.0

64.5

65.0

65.5

66.0

mode

 

 

 

 

 

 

dB(A)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operating sound

 

 

51.5

52.0

53.0

57.0

58.0

55.0

55.5

58.5

 

59.0

59.5

60.5

61.0

59.5

 

60.0

61.5

62.0

62.5

63.0

 

 

 

 

 

quiet mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ambient temperature

Cooling

 

 

 

 

 

 

 

 

 

 

 

-10°C DB +43°C DB

 

 

 

 

 

 

 

 

 

 

 

operating range

 

Heating

 

 

 

 

 

 

 

 

 

 

 

-20°C DB +15°C DB

 

 

 

 

 

 

 

 

 

 

 

Maximum number of indoor units

 

13

16

19

23

26

29

33

36

 

 

 

 

 

 

40

 

 

 

 

 

 

 

*Condenser actual pipe connections may vary from above pipe connections shown, please refer to technical manuals for full details.

*Please refer to tube sizing charts for pipe selections and pipe length parameters.

System example for ECOi 2 Way

Dimensions of unit combinations (ECOi 2 Way and 3 Way)

Connection SANYO make it possible to link outdoor units together for a large capacity (48HP)

Outdoor unit

Since all piping is concentrated into one

Concentration pipe shaft, you can minimise piping space and construction labour.

Indoor unit

8 to 16 HP

890 (Top plate dimension)

790 (Installation hole pitch)

890 (Top plate dimension)

920 (Installation hole pitch)

950 (Max. dimension)

1880

18 to 32 HP

 

 

890 (Top plate dimension)

100

890 (Top plate dimension)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

790 (Installation hole pitch)

200

790 (Installation hole pitch)

1780 (Installation hole pitch)

890 (Top plate dimension)

920 (Installation hole pitch)

950 (Max. dimension)

If indoor/outdoor units need servicing, a ball valve (optional) cuts off non-operational units to let other units stay running.

System limitations

Maximum number of combined outdoor units

3

Maximum HP of combined outdoor units

48HP

Maximum number of connectable indoor units

40

Indoor/outdoor unit capacity ratio

50-130%

Maximum actual piping length

150m

Maximum level difference (when outdoor unit is lower)

50(40)m

Maximum total piping length in one direction

300m

Indoor unit

Addition

If your indoor capacity load changes in the future, it’s easy to add on both indoor and outdoor units using the same piping.

(2 Way version illustrated)

34 to 48 HP

 

 

2870

 

 

 

 

890 (Top plate dimension)

100 890 (Top plate dimension)

100 890 (Top plate dimension)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Top plate dimension)

(Installation hole pitch)

(Max. dimension)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

890

920

950

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

790 (Installation hole pitch)

200

790 (Installation hole pitch)

200

790 (Installation hole pitch)

 

 

2770 (Installation hole pitch)

 

7

UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C

UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C

8

Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB

Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB

Page 5
Image 5
Sanyo SPW-CR365GXH8B, SPW-CR605GXH8B, SPW-CR365GXH56B, SPW-CR485GXH8B, C1305DXHN8 ECOi 2 Way Heat Pump VRF Inverter Systems