ECOi 2 Way Heat Pump VRF Inverter Systems
HP |
|
|
| 8 | 10 | 12 | 14 | 16 | 18 | 20 | 22 | 24 | 26 | 28 | 30 | 32 | 34 |
| 36 | 38 | 40 | 42 | 44 | 46 | 48 | |||
|
|
|
|
|
| C0705DXHN8 | C0905DXHN8 | C1155DXHN8 | C1305DXHN8 | C1405DXHN8 | 10 C0905DXHN8 | 10 C0905DXHN8 | 12 C1155DXHN8 | 14 C1305DXHN8 |
| 16 C1405DXHN8 | 16 C1405DXHN8 | 16 C1405DXHN8 | 16 C1405DXHN8 | 14 C1305DXHN8 | 16 C1405DXHN8 | 16 C1405DXHN8 | 16 C1405DXHN8 | 16 C1405DXHN8 | 16 C1405DXHN8 | 16 C1405DXHN8 | 16 C1405DXHN8 | |
Model |
|
|
|
|
|
|
|
| 8 C0705DXHN8 | 10 C0905DXHN8 | 10 C0905DXHN8 | 10 C0905DXHN8 |
| 10 C0905DXHN8 | 12 C1155DXHN8 | 14 C1305DXHN8 | 16 C1405DXHN8 | 10 C0905DXHN8 | 10 C0905DXHN8 | 12 C1155DXHN8 | 14 C1305DXHN8 | 16 C1405DXHN8 | 16 C1405DXHN8 | 16 C1405DXHN8 | 16 C1405DXHN8 | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 10 C0905DXHN8 | 10 C0905DXHN8 | 10 C0905DXHN8 | 10 C0905DXHN8 | 10 C0905DXHN8 | 12 C1155DXHN8 | 14 C1305DXHN8 | 16 C1405DXHN8 | |
Power supply |
|
|
|
|
|
|
|
|
|
|
|
| 380/400/415V - 3 phase/50,60Hz |
|
|
|
|
|
|
|
|
|
|
| ||||
Cooling capacity |
| kW |
| 22.40 | 28.00 | 33.50 | 40.00 | 45.00 | 50.40 | 56.00 | 61.50 | 68.00 |
| 73.00 | 78.50 | 85.00 | 90.00 | 96.00 |
| 101.00 | 107.00 | 113.00 | 118.00 | 124.00 | 130.00 | 135.00 | ||
Heating capacity |
| kW |
| 25.00 | 31.50 | 37.50 | 45.00 | 50.00 | 56.50 | 63.00 | 69.00 | 76.50 |
| 81.50 | 87.50 | 95.00 | 100.00 | 108.00 |
| 113.00 | 119.00 | 127.00 | 132.00 | 138.00 | 145.00 | 150.00 | ||
EER Cooling |
| kW |
| 3.74 | 3.54 | 3.50 | 3.45 | 3.38 | 3.63 | 3.54 | 3.51 | 3.49 |
| 3.44 | 3.43 | 3.41 | 3.38 | 3.50 |
| 3.47 | 3.47 | 3.45 | 3.42 | 3.43 | 3.40 | 3.38 | ||
COP Heating |
| kW |
| 4.05 | 4.06 | 3.91 | 3.91 | 3.79 | 4.06 | 4.06 | 3.97 | 3.96 |
| 3.88 | 3.84 | 3.85 | 3.79 | 4.00 |
| 3.94 | 3.89 | 3.91 | 3.86 | 3.83 | 3.83 | 3.79 | ||
|
|
|
| Running | A | 10.1/9.6/9.3 | 13.3/12.7/12.2 | 16.2/15.4/14.8 | 20.0/19.0/18.3 | 23.0/21.8/21.0 | 23.4/22.3/21.5 | 26.6/25.4/24.4 | 29.5/28.1/27 | 33.3/31.7/30.5 |
| 36.3/34.5/33.2 | 39.2/37.2/35.8 | 43.0/40.8/39.3 | 46.0/43.6/42.0 | 46.6/44.4/42.7 |
| 49.6/47.2/45.4 | 52.5/49.9/48.0 | 56.3/53.5/51.5 | 59.3/56.3/54.2 | 62.2/59.0/56.8 | 66.0/62.6/60.3 | 69.0/65.4/63.0 |
| Cooling | amperes |
|
| ||||||||||||||||||||||||
| Power | kW | 5.99 | 7.90 | 9.58 | 11.60 | 13.30 | 13.90 | 15.80 | 17.50 | 19.50 |
| 21.20 | 22.90 | 24.90 | 26.60 | 27.40 |
| 29.10 | 30.80 | 32.80 | 34.50 | 36.20 | 38.20 | 39.90 | |||
|
|
|
|
|
| |||||||||||||||||||||||
Electric |
|
|
| input |
|
| ||||||||||||||||||||||
rating |
|
|
| Running | A | 10.4/9.9/9.5 | 13.1/12.4/12.0 | 16.2/15.4/14.8 | 19.9/18.9/18.2 | 22.8/21.6/20.9 | 23.5/22.3/21.5 | 26.2/24.8/24.0 | 29.3/27.8/26.8 | 33.0/31.3/30.2 |
| 35.9/34.0/32.9 | 39.0/37.0/35.7 | 42.7/40.5/39.1 | 45.6/43.2/41.8 | 46.1/43.7/42.2 |
| 49.0/46.4/44.9 | 52.1/49.4/47.7 | 55.8/52.9/51.1 | 58.7/55.6/53.8 | 61.8/58.6/56.6 | 65.5/62.1/60.0 | 68.4/64.8/62.7 |
| Heating | amperes |
|
| ||||||||||||||||||||||||
| Power | kW | 6.17 | 7.75 | 9.60 | 11.50 | 13.20 | 13.90 | 15.50 | 17.70 | 20.70 |
| 22.60 | 23.10 | 26.10 | 28.00 | 29.30 |
| 31.20 | 30.60 | 34.70 | 34.20 | 37.10 | 37.90 | 42.00 | |||
|
|
|
|
|
| |||||||||||||||||||||||
|
|
|
| input |
|
| ||||||||||||||||||||||
Recommended fuse sizes (motor rated) |
| 32 |
| 40 |
| 32x2 |
| 1x40 |
| 1x40 | 2x40 |
|
| 2x32 |
|
| 1x32 |
| 3x40 | |||||||||
|
|
|
| 1x32 |
| 1x32 |
|
| 1x40 |
|
| 2x40 |
| |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
Dimensions | (H/W/D) | mm |
|
| 1887×890×890 (+60) |
|
| 1887×1880×890 (+60) |
|
|
| 1887×1880×890 (+60) |
|
|
|
|
| 1887×2870×890 (+60) |
|
|
| |||||||
Net weight |
| kg |
| 245 | 295 | 345 | 540 | 590 | 640 |
| 640 | 690 |
|
| 929 |
|
| 985 |
| 1035 | ||||||||
Air circulation |
| m3/min |
| 150 | 160 | 180 | 200 | 220 | 160+150 | 160+160 | 180+160 | 200+160 |
| 220+160 | 220+180 | 220+220 | 200+160+160 |
| 220+160+160 | 220+180+160 | 220+200+160 | 220+220+160 | 220+220+180 | 220+220+200 | 220+220+220 | |||
Piping |
| Gas |
|
| 3/4 (19.05) | 7/8 (22.22) |
|
|
| 1 1/8 (28.58) |
|
|
|
|
|
| 1 3/8 (34.92) |
|
|
|
|
|
| 1 5/8 (41.27) |
|
|
| |
| Liquid | Inches (mm) | 3/8 (9.52) |
| 1/2 (12.7) |
|
| 5/8 (15.88) |
|
|
|
|
|
|
|
| 3/4 (19.05) |
|
|
|
|
| ||||||
connection |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
| Balance |
|
|
|
|
|
|
|
|
|
|
| 1/4 (6.35) |
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
Operating sound normal |
|
| 54.5 | 55.0 | 56.0 | 60.0 | 61.0 | 58.0 | 58.5 | 61.5 |
| 62.0 | 62.5 | 63.5 | 64.0 | 62.5 |
| 63.0 | 64.5 | 65.0 | 65.5 | 66.0 | ||||||
mode |
|
|
|
|
| |||||||||||||||||||||||
| dB(A) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Operating sound |
|
| 51.5 | 52.0 | 53.0 | 57.0 | 58.0 | 55.0 | 55.5 | 58.5 |
| 59.0 | 59.5 | 60.5 | 61.0 | 59.5 |
| 60.0 | 61.5 | 62.0 | 62.5 | 63.0 | ||||||
|
|
|
|
| ||||||||||||||||||||||||
quiet mode |
|
|
|
|
| |||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Ambient temperature | Cooling |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
operating range |
| Heating |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
Maximum number of indoor units |
| 13 | 16 | 19 | 23 | 26 | 29 | 33 | 36 |
|
|
|
|
|
| 40 |
|
|
|
|
|
|
|
*Condenser actual pipe connections may vary from above pipe connections shown, please refer to technical manuals for full details.
*Please refer to tube sizing charts for pipe selections and pipe length parameters.
System example for ECOi 2 Way
Dimensions of unit combinations (ECOi 2 Way and 3 Way)
Connection SANYO make it possible to link outdoor units together for a large capacity (48HP)
Outdoor unit
Since all piping is concentrated into one
Concentration pipe shaft, you can minimise piping space and construction labour.
Indoor unit
8 to 16 HP
890 (Top plate dimension)
790 (Installation hole pitch) |
890 (Top plate dimension)
920 (Installation hole pitch)
950 (Max. dimension)
1880
18 to 32 HP |
|
| 890 (Top plate dimension) | 100 | 890 (Top plate dimension) | ||||||||
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
790 (Installation hole pitch) | 200 | 790 (Installation hole pitch) |
1780 (Installation hole pitch) |
890 (Top plate dimension)
920 (Installation hole pitch)
950 (Max. dimension)
If indoor/outdoor units need servicing, a ball valve (optional) cuts off
System limitations
Maximum number of combined outdoor units | 3 |
Maximum HP of combined outdoor units | 48HP |
Maximum number of connectable indoor units | 40 |
Indoor/outdoor unit capacity ratio | |
Maximum actual piping length | 150m |
Maximum level difference (when outdoor unit is lower) | 50(40)m |
Maximum total piping length in one direction | 300m |
Indoor unit
Addition
If your indoor capacity load changes in the future, it’s easy to add on both indoor and outdoor units using the same piping.
(2 Way version illustrated)
34 to 48 HP |
|
| 2870 |
|
|
|
| |||
890 (Top plate dimension) | 100 890 (Top plate dimension) | 100 890 (Top plate dimension) | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (Top plate dimension) | (Installation hole pitch) | (Max. dimension) | ||
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
| 890 | 920 | 950 | ||
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
790 (Installation hole pitch) | 200 | 790 (Installation hole pitch) | 200 | 790 (Installation hole pitch) |
|
| 2770 (Installation hole pitch) |
|
7 | UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C | UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C | 8 |
Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB | Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB |