ALARM RECORDING

Alarm Recording Counter Display

XDuring alarm recording, “AL” will be flashing on the digital display.

XIf the ON SCREEN switch is set to the “ON” position, the number of alarms will flash on the monitor screen.

XThe maximum display number of alarm recordings is “999”, at the next alarm recording the counter will indicate “000”.

XWhen the (ALARM TIME) menu is displayed, press the MENU RESET button to reset the alarm counter to “000” (all the data of the (ALARM TIME) menu is reset).

Connections to the ALARM IN/OUT Terminals

XAlarm input signal

Connect a make-contact (no voltage) switch between the ALARM IN and COM terminals.

XAlarm output signal

Normally DC 5V are output between the ALARM OUT and the COM terminals. When an alarm input (trigger) is received and the unit is recording, the output falls to 0V. Once the alarm recording is over, the output returns to DC 5V.

Checking the Alarm Recordings Time

1Press the MENU button until the (ALARM TIME) menu is displayed.

øThe number of alarm recordings, and the 8 most recent alarm recording times are displayed.

@@@@@@<ALARM@TIME>

@@@@008@12-25@19:00

@@@@@@@@11-25@23:00

@@@@@@@@11-25@15:00

@@@@@@@@10-25@08:00

@@@@@@@@10-25@06:00

@@@@@@@@09-25@20:00

@@@@@@@@09-25@16:35

@@@@@@@@09-25@10:52

NOTE:

XThe data for the previous alarm recordings is erased.

2Press the SEARCH/AUDIO ON button, the normal screen is displayed.

NOTE:

XIf the MENU RESET button is pressed while the (ALARM TIME) menu is displayed, the displayed data is erased. “AL” will be erased from the digital display.

English

21