RECORDING USING AN EXTERNAL TIMER INPUT

Recording can be controlled by an external start/stop signal input at the EXT TIMER IN terminal.

Example 3: To record using the signal input at the EXT TIMER IN terminal, in 24-hour mode.

XFollow the Before starting steps, under “NORMAL RECORDING”.

NOTE:

XExternal timer input recording can only be set on the 9th line (EXT) of the (TIMER SET) menu.

1Press the MENU button until the (TIMER SET) menu is displayed.

2Press the * (or +) button, until the “SPD” (recording speed) position of the “EXT” line starts flashing.

3Press the l (or j) button to select the recording speed mode (ex: 24), then press the * button.

ø“N” will start flashing.

4Press the l (or j) button to select “Y”.

@@@@@@<TIMER@SET>

WEEK@START@@STOP@@@SPD

SUN@@--:--@@--:--@@---

@N

MON@@--:--@@--:--@@---

@N

TUE@@--:--@@--:--@@---

@N

WED@@--:--@@--:--@@---

@N

THU@@--:--@@--:--@@---

@N

FRI@@--:--@@--:--@@---

@N

SAT@@--:--@@--:--@@---

@N

DLY@@--:--@@--:--@@---

@N

EXT@@*****@@*****@@@24@Y

5Follow steps F and G under “PROGRAM TIMER RECORDING on page 23”.

øWhen an external signal is input, “E” will light on the digital display and recording will take place.

NOTES:

XOther timer recordings using the standard procedure can also be programmed.

XThe external input signal must be input at the EXT TIMER IN terminal.

English