Sanyo TVQ-EXA089K Model Name, Tvq-Exack, General, Defrost electric, Electrical, Components

Models: TVQ-EXA089K TVQ-EXA029K. TVQ-EXACK

1 28
Download 28 pages 12.25 Kb
Page 5
Image 5
TVQ-EXACK

Model Name

TVQ-EXACK

General

 

 

 

 

 

 

 

 

 

 

Applications

 

Medium Temperature

 

Frozen Food

 

 

 

 

 

 

Refrigerant

 

R-404A

 

R-404A

 

 

 

 

 

Cooling Capacity

1194 BTU/h/case (350W)

 

1501 BTU/h/case (440W)

 

 

 

 

 

 

Discharge Air

 

24°F (-4.5°C)

 

-12°F (-24.4°C)

 

 

 

 

 

Evaporator Temperature

19°F (-7.2°C)

 

-20°F (-28.9°C)

 

 

 

 

 

 

 

Defrost (electric)

Medium Temperature & Frozen Food

Frequency (hr)

 

 

12

 

 

 

 

Temp Term (°F)

 

50

 

 

 

 

 

Failsafe (min)

 

 

30

 

 

 

 

 

 

 

 

Electrical

 

Medium Temperature & Frozen Food

 

 

 

1 phase 208V

 

 

 

 

 

 

 

 

 

(W)

 

(A)

 

 

 

 

 

 

Defrost Heater

 

1445

 

6.95

 

 

 

 

 

 

 

 

1 phase 120V

 

 

 

 

 

 

 

 

 

(W)

 

(A)

 

 

 

 

 

Anti-condensation Heater

82

 

0.68

 

 

 

 

 

 

Fan Motor

 

Standard

23

 

0.34

 

 

 

 

 

 

 

 

High Efficiency

5.5

 

0.11

 

 

 

 

Components

Medium Temperature & Frozen Food

Defrost Heater

 

1-phase 208V 1445W

 

 

Anti-condensation Heater

1-phase 120V 82.0W

 

 

 

Fan Motor

 

Standard

SPFBC51 x 1

 

 

 

 

 

 

High Efficiency

SSC2B12BRHBV1 x 1

 

 

 

Fan Blade Pitch

109×1

 

 

 

 

 

Pipe Diameter

 

Liquid Pipe ⅜”

 

Suction Pipe ¾”

 

 

Refrigerant Type

R-404A

 

 

 

 

Measurements

Medium Temperature & Frozen Food

Outer Dimensions

35 ½” (H)× 37 ¼” (W) × 70 ⅞” (L)

 

 

 

Display Area

 

12.8 sq.ft.

 

 

Effective Capacity

15.6 cu.ft.

 

 

 

Weight

 

397 lbs

 

 

Waste Outlet Dimensions

1 ½”

 

 

 

 

 

 

￿Standard Ambient Conditions : Indoor temperature 75°F (24°C), relative humidity 55%, wind speed under 39.4 fpm.

￿All specifications are based upon temperature, humidity, and wind speed values equal to or less than Standard Ambient Conditions.

￿Products described in this manual are designed for indoor use only. Products should not be exposed to direct sunlight.

￿Fan motors are available in standard-type (AC fan motors) or high-efficiency type (DC fan motors).

5

Page 5
Image 5
Sanyo TVQ-EXA089K service manual Model Name, Tvq-Exack, General, Defrost electric, Electrical, Components, Measurements