3.7Joining Instructions
3.7.1Applying gasket (for connecting cases or installing side panels).
①Make sure that all merchandisers are resting level.
②Make sure that all required parts for joining are present (gasket, bolts, joint covers, nuts, etc.).
③Remove wire racks, deck pans, and air grilles from the far right and left ends of each case being joined.
④Place gasket along the areas shown in bold in the drawing at right. When connecting two cases, apply gasket to one case only.
Perimeter gasket is required by NSF.
Do not stretch or twist gasket when applying.
Do not leave gaps. Always overlap gasket rather than leaving gaps.
Gasket ends that are open must be sealed off by applying silicone at the installation site.
Insufficient or improper sealing may lead to insufficient cooling and condensation.
Gasket
9