SETTINGS AND

Line phase adjustment

When using a camera switcher to connect two cameras or more to one monitor, there may be a vertical roll of the images when switched, if the phases differ. In such a case, adjust as described below.

Using the camera switcher, switch the display on the monitor from camera 1 to camera 2.

Adjust the L-PHASEvolume control on camera 2 until the vertical roll of the image stops.

If more than two cameras are used, please repeat this procedure for all the cameras.

NOTE:

If the vertical roll cannot be corrected by adjusting the L-PHASEvolume on camera 2, try adjusting the L-PHASEvolume on camera 1. If it still cannot be corrected, please check that the polarity of the power cords of all connected devices is correct.

OUT

IN IN

1 2 3 4

L-PHASE