PARTS NAMES AND FUNCTIONS
These screws are used to attach the camera unit to the base. Tighten the four screws evenly when attaching the camera unit.
2 Screw openings for base installationThese openings are to attach the base to the ceiling or a wall using the four supplied tapping screws.
3 CAMERA (VIDEO) OUT terminal screwVideo signal output terminal. Insert the center wire of the coaxial cable into the CAMERA OUT terminal, then tighten the screw to secure it.
4 GND (ground) terminal screwVideo signal ground terminal. Insert the shielding mesh of the coaxial cable under the GND terminal plate, then tighten the screw to secure it.
5 Cabling tab |
When the cables cannot be run behind the ceiling, etc., remove |
this tab to allow the coaxial cable to go through. |
With this camera use only the 24 V AC power adaptor model No.
Use a 3 wire grounded cable (22 AWG or more), and connect as shown by the illustration.
CAUTION:•To prevent camera and/or AC adaptor failure, pay close attention polarity when making the connections.
•To prevent fire hazard any UL listed wire rated
| GND |
AC | AC |
|
This cover will protect the lens from dust and damage. Turn the cover in the direction of the arrow, shown on the illustration, to remove it. To install the cover, align the tabs (A) with the openings, then turn it in the opposite direction.
English 5