FLANGE-BACK ADJUSTMENT

CS mount ring

Flange-back lock screw

If the pick-up surface is not correctly positioned with relation to the lens focal point, the picture will be out of focus (in particular when using auto-iris power zoom lenses, sold separately). If that is the case, adjust the flange-back position as described below.

1Before installing the lens, check that the two flange-back lock screws have been tightened.

If the flange-back lock screws are loose, the CS mount ring will not be secured and it will not be possible to adjust the flange-back.

2Fully install the lens, then loosen the two flange-back lock screws.

3Set the zoom lens to the maximum telephoto position (TELE), then set the focus using the focus ring on the lens.

4Set the zoom lens to the maximum wide angle position (WIDE), then set the focus by turning the CS mount ring.

5Repeat steps 3 and 4 until the image stays in focus when changing from a telephoto shot to a wide angle shot. When the setting is complete, tighten the flange-back lock screws.

English 13