SETTINGS

Line phase adjustment

When using a camera switcher to connect 2 cameras or more to one monitor, there may be a vertical roll of the images when switched. In such a case, set as described below.

1Set the Sync switch to the L-Lposition.

2Switch the display on the monitor from camera 1 to camera 2.

Adjust the LINE PHASE volume on camera 2 until the vertical roll of the image stops.

If more than two cameras are used, please repeat this procedure for all the cameras.

CAUTION:

If the vertical roll cannot be corrected by setting the LINE PHASE volume on camera 2, try setting the LINE PHASE volume on camera 1. If it still cannot be corrected, please check that the polarity of the power cords of all connected devices is correct.

(Monitor)

EI OFF

 

 

2

EI ON

INT

 

 

1

L-L

 

 

 

 

 

 

 

LINE

PHASE

14English