6.5Camera/Lens Installation

1.Loosen the two screws holding the camera bracket to the base. It is not necessary to remove them completely. See Figure 3.

Camera

Bracket

Loosen These

Screws

Figure 3: Removing the Camera Bracket

2.Remove the camera bracket from the base. If you are using the feed-through feature, refer to Section 6.8.3 at this time.

Mounting fixed lens cameras in VSE-2300 and VSE-2400 Series Housings.

1.Attach the lens to the camera.

2.Use the 1/4-20 x 3/8-inch screw to mount the camera to the camera bracket. The lens should extend approximately 6 mm (0.25-inch) from the front of the camera bracket. See Figure 4.

Camera

Camera

Bracket

VSE-2400 Series:

3.Attach the lens to the camera.

4.Use the various 1/4-20 screws and spacers provided to mount the camera and the lens to the camera bracket.

6.6Camera/Lens Wiring

WARNING: Only use the cables specified under "INSTALLATION, Cable Requirements" for wiring of all cameras and lenses.

6.6.1Fittings

1.The two large 1/2-inch NPT fittings accept round cable with diameters from 4.3 mm (0.17-inch) to 11.9 mm (0.47-inch). The small fittings will accept cables with diameters from 4.6 mm (0.181-inch) to 7.9 mm (0.312- inch).

Be sure to securely tighten all fittings to ensure a liquid-tight seal. Failure to do so could allow water to enter the housing and damage the camera and lens.

If a sealant is to be used, be sure it is a neutral cure type. Sealants that release acetic acid may harm camera electronics.

Use of "drip loops" is recommended on the wiring outside of the rear end cap.

6.6.2Conduit

These housings are designed to allow conduit to be directly connected.

1.Remove the rear fittings and attach the conduit and conduit fittings directly to the housing rear cap. The holes accept 1/2-inch conduit fittings and PG 13.5 conduit fittings. Any unused holes can be covered using the plugs provided in the hardware kit.

6.6.3Feed-through Wiring

These housings have the capability of having the cabling feed through the foot of the housing. This requires the use of feed-through mounts like the MTS-2000, or MTS-2030 J-mount.

1.Prior to mounting the camera. Remove the two dome plugs located inside the housing. See Figure 7.