Important

IMPORTANT!

Please Read Before Starting

This air conditioning system meets strict safety and operating standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently.

For safe installation and trouble-free operation,you must:

ÚCarefully read this instruction booklet before beginning.

ÚFollow each installation or repair step exactly as shown.

ÚObserve all local, state, and national electrical codes.

ÚPay close attention to all warning and caution notices given in this manual.

When Transporting

……………………………………………………………………

Be careful when picking up and moving the indoor and outdoor units. Get a partner to help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin aluminum fins on the air conditioner can cut your fingers.

When Installing

……………………………………………………………………

…In a Room

Properly insulate any tubing run inside a room to prevent “sweating” that can cause dripping and water damage to walls and floors.

…In Moist or Uneven Locations

CAUTION

This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death.

This symbol refers to a hazard or unsafe practice which can

result in personal injury or product or property damage.

Use a raised concrete pad or concrete blocks to provide a solid, level foundation for the outdoor unit. This prevents water damage and abnormal vibration.

…In an area with High Winds

Securely anchor the outdoor unit down with bolts and a metal frame. Provide a suitable air baffle.

…In a Snowy Area

(for Heat Pump-type Systems)

If Necessary, Get Help

These instructions are all you need for most installation sites and maintenance conditions. If you require help for a special problem, contact our sales/service outlet or your certified dealer for additional instructions.

In Case of Improper Installation

The manufacturer shall in no way be responsible for improper installation or maintenance service, including failure to follow the instructions in this document.

SPECIAL PRECAUTIONS

When Wiring

……………………………………………………………………

ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH. ONLY A QUALIFIED, EXPERIENCED ELECTRICIAN SHOULD ATTEMPT TO WIRE THIS SYSTEM.

Do not supply power to the unit until all wiring and tubing are completed or reconnected and checked.

Highly dangerous electrical voltages are used in this system. Carefully refer to the wiring diagram and these instructions when wiring. Improper connections and inadequate grounding can cause accidental injury or death.

Ground the unit following local electrical codes.

Connect all wiring tightly. Loose wiring may cause overheating at connection points and a possible fire hazard.

Install the outdoor unit on a raised platform that is higher than drifting snow. Provide snow vents.

When Connecting Refrigerant Tubing

……………………………………………………………………

Execute enough ventilation in case refrigerant gases leak during operations. Be careful that the contact of the refrigerant gases with the flare will cause the generation of poisonous gases.

Keep all tubing runs as short as possible.

Use the flare method for connecting tubing.

Apply refrigerant lubricant to the matching surfaces of the flare and union tubes before connecting them, then tighten the nut with a torque wrench for a leak-free connection.

Check carefully for leaks before starting the test run.

NOTE

Depending on the system type, liquid and gas lines may be either narrow or wide. Therefore, to avoid confusion the refrigerant tubing for your particular model is specified as either “narrow” or “wide” rather than as “liquid” or “gas”.

When Servicing

……………………………………………………………………

Turn the power OFF at the main power box (mains) before opening the unit to check or repair electrical parts and wiring.

Keep your fingers and clothing away from any moving parts.

Clean up the site after you finish, remembering to check that no metal scraps or bits of wiring have been left inside the unit being serviced.

2S4359128

Page 2
Image 2
Sanyo XS1852, PNR-XS2432 installation instructions Please Read Before Starting

PNR-XS2432, XS1852 specifications

The Sanyo XS1852 and PNR-XS2432 are dual offerings that exemplify cutting-edge technology in the realm of compact air conditioning systems. Sanyo, a trusted brand in HVAC solutions, has built these units to cater to both efficiency and comfort, making them ideal for residential and commercial applications.

The Sanyo XS1852 is a wall-mounted split air conditioning system known for its sleek design and powerful performance. It features advanced inverter technology, allowing for variable speed operation. This means the compressor adjusts its speed based on the cooling demand, resulting in significant energy savings and enhanced comfort. The XS1852 operates quietly, producing minimal noise, making it suitable for bedrooms and quiet spaces.

One of the standout features of the XS1852 is its intelligent air distribution. The unit is equipped with multiple airflow settings and swing functions that ensure the air is evenly distributed throughout the room. This feature helps maintain a consistent temperature, avoiding hot or cold spots. The XS1852 also boasts a user-friendly remote control and an intuitive LED display, making it easy to adjust settings even from a distance.

Meanwhile, the PNR-XS2432 is designed for larger spaces, with robust cooling capacities. This ceiling cassette model offers a discreet installation option, fitting seamlessly into various environments. It features a four-way airflow system that enables effective air distribution from all sides, ensuring maximum comfort even in larger rooms. The PNR-XS2432 is also designed with a high energy efficiency rating, providing both cost savings and reduced environmental impact.

Both units incorporate advanced filtration technology, including a multi-layer filtration system that captures dust, allergens, and odors. This feature not only enhances air quality but also contributes to a healthier indoor environment.

Another important characteristic of these models is their compatibility with smart home systems. Users can easily connect these units to their smart devices, allowing remote access and control via mobile applications. This added convenience makes it possible to schedule cooling cycles and monitor energy usage, promoting smarter energy consumption.

In summary, the Sanyo XS1852 and PNR-XS2432 represent a blend of innovative technology, energy efficiency, and user-centric design. They are ideal solutions for anyone seeking reliable and effective air conditioning options that enhance comfort while minimizing environmental impact.