Saunatec 1108-60, 1108-24 Mounting Sauna Heater And Control, Placing Of Rocks, Electrical Hook-Up

Models: 1108-46 1108-24 1108-60

1 13
Download 13 pages 53.15 Kb
Page 3
Image 3
SECTION 2: MOUNTING SAUNA HEATER AND CONTROL

Installation & Operation Instructions

3

SECTION 2: MOUNTING SAUNA HEATER AND CONTROL

Carefully locate the heater according to the dimensions shown in Diagram 1.

The supplied mounting block and control must be located and mounted according to Diagram 1B. (This is to prevent the control from being placed in an unsafe location.)

SECTION 3: PLACING OF ROCKS

The rocks supplied with the heater have been chosen to provide the best heater performance. Use of any other type of rock may void the heater’s warranty. Never operate the heater without rocks in place! Rinse the rocks with water before placing in the heater. Place the rocks loosely to keep the elements vertical and so the air can circulate through the heater. Packing the rocks too tightly may cause the heater high limit switch to trip. The rocks must fully cover the heating elements.

SECTION 4: ELECTRICAL HOOK-UP

Electrical installation must be made by a licensed electrician in accor- dance with the National Electrical Code and local regulations.

To determine the correct wire size, refer to Diagram 2. Use copper supply wire only, suitable for minimum 90 degrees C. The heater must be grounded! See the heater wiring diagrams for proper connections.

Remove screws from the back cover to gain electrical access. Refer to Diagram 10.

SECTION 5: GUARD RAIL

To reduce the risk of injury (hot surface of sauna heater opening) install the heater guard rail with the clearances and dimensions shown in Diagram 1.

4211-86-G 09-23-05

Warning

Fire sprinkler systems used

inside any sauna room

should be properly rated for sauna room temperatures.

Do not pour chlorinated

pool or spa water on heater.

Excessive water use on

heater may cause damage

and void warranty.

Do not install a shower in

the sauna room.

Electric Shock Hazard - High voltage exists within this equipment. There are no user serviceable parts in this equipment. All installa-

tion and service to this

equipment should be per- formed by qualified licensed personnel in accordance with local and national codes.

Do not construct sauna room so as to restrict air flow through the bottom of the heater.

Packing the rocks too tightly may cause the heater high limit switch to trip.

314 SKLH 20C

Page 3
Image 3
Saunatec 1108-60, 1108-24, 1108-46 manual Mounting Sauna Heater And Control, Placing Of Rocks, Electrical Hook-Up, Guard Rail