Schneider Electric C3419M-D (11/08) manual Switch Settings, Special Systems, Serial Port Settings

Models: C3419M-D (11/08)

1 16
Download 16 pages 28.89 Kb
Page 8
Image 8
Switch Settings

Switch Settings

Special Systems WARNING: If you are using Pelco D-type or P-type control, your system may not operate if the baud rate and address switches are not set correctly. The switches are set at the factory at the defaults for Pelco D-type control (2400 baud and address 1).

Table E. Switch Settings for SW2

Special Systems

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch Number

1

2

3

4

5

6

7

8

9

10

 

 

 

 

 

 

 

 

 

 

 

AD-32 Preset System

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CM9502 Setting

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vicon

 

Not currently available; SW2-3 is reserved for future use.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Serial Port Settings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch Number

1

2

3

4

5

6

7

8

9

10

 

 

 

 

 

 

 

 

 

 

 

RS422

 

 

 

OFF

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS485, 4-Wire

 

 

 

OFF

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS485, 2-Wire

 

 

 

ON

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pelco D or P Protocol Baud Rate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch Number

1

2

3

4

5

6

7

8

9

10

 

 

 

 

 

 

 

 

 

 

 

2400 Baud (Default for D-type Control)

 

 

 

 

 

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

4800 Baud (Default for P-type Control)

 

 

 

 

 

ON

OFF

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

9600 Baud

 

 

 

 

 

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Video Cable Type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch Number

1

2

3

4

5

6

7

8

9

10

 

 

 

 

 

 

 

 

 

 

 

Coaxial Cable

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

UTP Cable

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dome Termination

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch Number

1

2

3

4

5

6

7

8

9

10

 

 

 

 

 

 

 

 

 

 

 

Terminated

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

Not Terminated

 

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

8

C3419M-D (11/08)

Page 8
Image 8
Schneider Electric C3419M-D (11/08) manual Switch Settings, Special Systems, Serial Port Settings, Video Cable Type