Schumacher 00-99-000659/0606, 94026879 Powering a 110V AC Device, Troubleshooting the Inverter

Models: 00-99-000659/0606 94026879 00-99-000659

1 12
Download 12 pages 19.22 Kb
Page 8
Image 8

POWERING A 110V AC DEVICE

There are two-110 volt AC POWER outlets located on the front panel.

To operate a 110 volt AC device:

1.Make sure the device to be powered is OFF.

2.Plug the 110V AC device power cord into a AC POWER outlet located on the front panel. Push the INVERTER switch located on left side of front panel to ON (I). The digital display will show 0.

3.Turn ON the 110V AC device. The digital display will show the draw of watts from device plugged in.

4.If a device will not operate properly when first connected to the inverter,

push the INVERTER rocker switch ON (I), OFF (0), and ON (I) again in quick succession. If this procedure is not successful, it is likely the PP- 18400CI inverter does not have the required capacity to operate the device(s) in question. Make sure the wattage does not exceed 400.

5.Turn OFF (0) the INVERTER switch when finished.

6.Charge the PP-18400CI as soon as possible after each use.

CAUTION: Incorrect operation of your inverter may result in damage and per- sonal injury. Electrical current on a 110 volt circuit can be very dangerous.

110V AC electrical device example run-time chart

Appliance Type

Estimated Wattage

Estimated Time*

Spotlights, Sump Pumps, DVD

100 Watts

1.3 Hours

Players

 

 

Faxes, TVs, Small Power Tools

150 Watts

50 Minutes

Computer Printer, Medium Power

200 Watts

40 Minutes

Tools, Blenders

 

 

The maximum continuous load is 400 watts.

*NOTE: Estimated run-times. Actual time may vary. Times are based on the internal battery being fully charged.

TROUBLESHOOTING THE INVERTER

1.Alarm sounds, and device plugged in shuts off.

Continuous load demand or wattage exceeds 400 watts. Push INVERTER switch to the OFF (0) position.

Determine source of problem, and re- solve it before reusing the inverter.

2.The Alarm Sounds.

Voltage from the internal battery drops to approximately 10.5 volts. When the power input drops to ap- proximately 11 volts an alarm will sound for an extended period.

3.Inverter shuts down.

The PP-18400CI inverter temperature exceeds 145º F.

NOTE: The PP-18400CI is fitted with a cooling fan that runs continuously for loads drawing 25 watts or higher. If cooling fan is unable to maintain a cool enough temperature for safe operation, inverter will automatically shut down. If inverter automatically shuts down or a continuous audible alarm is heard, push INVERTER switch to the OFF (0) position. Deter- mine source of problem, and resolve it before reusing the inverter.

Page 8
Image 8
Schumacher 00-99-000659/0606, 94026879 Powering a 110V AC Device, 110V AC electrical device example run-time chart