LOAD ERROR:

The tested battery is larger than 1200CCA or 120AH. ERR Or the clamps are not connected properly.

9.Press “ENTER” return to step 4 or remove the test clamps from the battery posts after completion of testing.

*The operator is asked if any accessories are left on as a possible cause. If accessories are left on, the operator is instructed to charge and retest the battery. If accessories are not left on, the operator is instructed to replace the battery, since the charging system is working and a good battery should have accepted a charge.

6

Page 6
Image 6
Schumacher BT-250 owner manual Load Error