- 10 -
inverter to reset. To reset: press the “ TeST” button (stops
ow of electricity to outlet) on the outlet face. Next, press
the “RESET” button (restores ow of electricity to outlet)
on the outlet face.
LeDs and Audio Alarms
Green – Power on
Red light and/or Audio Alarm
Current overload – Red led glows for a short time and
inverter shuts down. Current load too high for inverter.
Reduce current demand.
Voltage overload – Red led glows and inverter shuts
down. Voltage range of 15.5V ± 0.5V d C too high for
inverter. Voltage exceeding 16 volts may damage the
inverter. Reduce voltage range to 12 volts to 14 volts.
Voltage Shortage – Alarm soun ds indicating voltage is
getting low (10.5V ± 0.3V dC). Inverter shuts do wn and
red light glows when voltage falls below 10.0V ± 0.3V dC.
Inverter needs voltage source bet ween 12 volts and 14
volts.
Temperature overload – Red led glows for a short time
and inverter shuts down. Provide ample ventilation for
inverter to restart.
Analogic output Power display - shows AC continuous
power consumed. Five lights indicate half of the continu-
ous output power and ten lights indic ate full continuous