Troubleshooting

Table 6-1. Alarm Conditions (4 of 4)

Alarm Condition

What It Indicates

What To Do

 

 

 

Primary Clock Failed

A failure of the configured

H Check that the network cable

 

 

primary clock source for the

is securely attached at both

 

 

unit was detected and the

ends.

 

 

secondary clock is

H Contact your network provider.

 

 

providing the timing for the

 

 

 

 

 

unit.

 

 

 

This condition clears when

 

 

 

the configured primary

 

 

 

clock is restored.

 

 

 

 

Self-Test Failure

The unit did not pass its

H Reset the unit.

 

 

basic verification tests

H Contact your service

 

 

when it was powered on or

 

 

representative.

 

 

reset.

 

 

 

 

 

 

SLV Timeout,

An excessive number of

Verify that the network LMI is up.

DLCI nnnn,

SLV communication

If it is, contact your network

frame relay link 1, 2

responses from the remote

service provider.

 

 

system have been missed

 

 

 

on the specified multiplexed

 

 

 

DLCI and link.

 

 

 

If the frame relay link is

 

 

 

Net1-FR1, the timeout is on

 

 

 

the network FrameRly1

 

 

 

timeslot assignment.

 

 

 

When a hardware bypass-

 

 

 

capable device has been

 

 

 

detected at the other end of

 

 

 

the PVC and this condition

 

 

 

occurs, only user data for

 

 

 

EDLCI 0 will be transmitted

 

 

 

as long as the condition

 

 

 

exists.

 

 

 

 

Two Level-1 Users

Another user with Level-1

Wait until no other Level-1

Accessing Device

security access is currently

users are accessing the unit if

 

 

accessing the unit.

testing or configuration will be

 

 

Be aware that actions of

performed..

 

 

 

 

 

the other user may override

 

 

 

your test commands and

 

 

 

configuration changes.

 

 

 

 

Yellow at Network 1

A yellow alarm signal is

 

 

 

received on the network

 

 

 

interface.

 

 

 

H Network cable problem.

H Check that your network cable

 

 

 

is securely attached at both

 

 

 

ends.

 

 

H T1 facility problem.

H Contact your network provider.

 

 

 

 

1

nnnn indicates a DLCI number of 16 through 1007.

 

2

frame relay link is one of the following:

 

± Net1-FR1. The frame relay link specified for the network interface, Network 1.

± Port-1. The frame relay link associated with the user data port.

6-10

May 2000

9123-A2-GB20-00

Page 160
Image 160
Paradyne 9123 manual Alarm Conditions 4 What It Indicates What To Do