Troubleshooting

Physical Tests

A FrameSaver 9123 unit's physical tests screen for the network interface is shown below.

Main Menu Test [Network Physical Tests/Data Port Physical Tests]

This example shows the Network Physical Tests screen, for the model with 64 PVCs and the FLEX SLV upgrade.

Physical Tests Screen Example

main/test/network

 

 

9123-C-SLV

Device Name: Node A

 

 

3/26/2000 23:32

 

 

NETWORK 1 PHYSICAL TESTS

 

Test

 

Command

Status

Results

Local Loopbacks

 

 

 

Line Loopback:

Start

Inactive

0:00:00

Payload Loopback:

Start

Inactive

0:00:00

Repeater Loopback:

Start

Inactive

0:00:00

Remote Loopbacks

 

 

 

Send Line Loopback: Down

Send

Inactive

0:00:00

Pattern Tests

 

 

 

Send:

user-defined 0a0a

Stop

Active

0:00:00 - Errors 99999+

Monitor: user-defined 0a0a

Stop

Active

0:00:00 - Errors 99999+

±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit InjectErr ResetMon

The ResetMon function key at the bottom of the screen only appears when a Monitor 511 test pattern is Active. Select ResetMon to reset the monitor pattern error counter.

CAUTION:

You should not run these tests with frame relay equipment attached; you must disconnect the frame relay equipment and use external test equipment.

6-20

May 2000

9123-A2-GB20-00

Page 170
Image 170
Paradyne 9123 manual Physical Tests Screen Example