Troubleshooting

Table 6-1. Alarm Conditions (3 of 4)

Alarm Condition

What It Indicates

What To Do

 

 

 

LMI Down,

The Local Management

For user data port:

frame relay link 2

Interface is down for the

H Check that the DTE cable is

 

specified frame relay link.

 

securely attached at both

 

 

(cont'd)

 

ends.

 

 

H Verify that Transmit Clock

 

 

Source and Invert Transmit

 

 

Clock options are properly

 

 

configured.

 

 

H Verify that Frame Relay

 

 

Performance Statistics show

 

 

LMI frames being received. If

 

 

no frames are being received:

 

 

± Check the attached device.

 

 

± Verify that the LMI Protocol

 

 

setting reflects the LMI type

 

 

being used.

 

 

 

LOS at Network 1

A Loss of Signal (LOS)

 

 

condition is detected on the

 

 

network interface. Clears

 

 

when the ratio of ones to

 

 

zeros received is greater

 

 

than or equal to 12.5%.

 

 

H Network cable problem.

H Check that the network cable

 

 

is securely attached at both

 

 

ends.

 

H No signal is being

H Check far-end FrameSaver

 

transmitted at the far-end

unit status.

 

FrameSaver unit.

 

 

H T1 facility problem.

H Contact your network provider.

 

 

 

Network Com Link

The communication link for

Check the router connected to

Down

the COM port is down and

the COM port.

 

the COM port is configured

 

 

for Net Link.

 

 

 

 

OOF at Network 1

An Out of Frame (OOF)

 

 

condition is detected on the

 

 

network interface.

 

 

H Incompatible framing

H Check that the framing format

 

format between the

for the network interface is

 

network and the

correct.

 

FrameSaver unit.

 

 

H Network cabling

H Check that the network cable

 

problem.

is securely attached at both

 

 

ends.

 

H T1 facility problem.

H Contact your network provider.

 

 

 

2 frame relay link is one of the following:

± Net1-FR1. The frame relay link specified for the network port, Network 1.

± Port-1. The frame relay link associated with the user data port.

9123-A2-GB20-00

May 2000

6-9

Page 159
Image 159
Paradyne 9123 manual Alarm Conditions 3 What It Indicates What To Do