Troubleshooting

Test Timeout Feature

A Test Timeout feature is available to automatically terminate a test (as opposed to manually terminating a test) after it has been running a specified period of time.

It is recommended that this feature be used when the FrameSaver unit is remotely managed through an inband data stream (PVC). If a test is accidently commanded to execute on the interface providing management access, control is regained when the specified time period expires, automatically terminating the test.

To use this feature, enable the Test Timeout configuration option, and set a duration for the test to run in the Test Duration (min) configuration option (see Configuring General System Options in Chapter 3, Configuration).

NOTE:

These configuration options do not pertain to tests commanded by the DTE, like a DTE-initiated External Loopback.

Starting and Stopping a Test

Use this procedure to start, monitor, or abort specific tests. To abort all active tests on all interfaces, see Aborting All Tests.

When the status of a test is . . .

The only command available is . . .

Inactive

Start

Active

Stop

Start or stop an individual test using the same procedure.

NOTE:

If the Service Type setting on the Easy Install screen changes, all currently active tests are stopped.

9123-A2-GB20-00

May 2000

6-15

Page 165
Image 165
Paradyne 9123 Starting and Stopping a Test, Test Timeout Feature, When the status of a test is Only command available is