Operation and Maintenance

Viewing LEDs and Control Leads

The FrameSaver 9123 unit's faceplate includes LEDs (light-emitting diodes) that provide status on the unit and its interfaces.

9123-C

 

OK

ALM

TEST

FR

SIG OOF

ALM

OK

FrameSaverTM® SFLEXV

 

 

 

 

 

 

 

 

 

 

 

System

 

 

 

Network

 

 

 

Port

 

 

 

 

 

 

 

 

00-16707

The Display LEDs and Control Leads screen allows you to monitor a remote unit and is useful when troubleshooting control lead problems. The appropriate interfaces are shown on this screen, with the appropriate status highlighted.

Main Menu → Status → Display LEDs and Control Leads

Display LEDs & Control Leads Screen

main/status/leds

 

9123-C-SLV

Device Name: Node A

 

3/26/2000 23:32

 

DISPLAY LEDS & CONTROL LEADS

 

SLOT: 1 ± T1 FR NAM

 

GENERAL

NETWORK1

PORT-1

OK

Sig

OK

Alarm

OOF

TXD

Test

Alm

RXD

 

LMI OK

DTR

FR Mode

 

RTS

±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±

ESC for previous menu

MainMenu

Exit

Refresh

 

 

Refresh the screen to view control lead transitions. LED and control lead descriptions are in the sections that follow.