SNMP MIBs and Traps, and RMON Alarm Defaults

Table B-12. Static DLCI Alarm Defaults ± NetScout Area (2 of 2)

Item

Sample Type 1

MIB/Tag/OID 2

Interval

Event Type

Rising Falling

Threshold Threshold

Default Default

Tx Frames

D

MIB: pdn_FrExt.mib (E)

60 secs

None

Must be

0

Exceeding CIR

 

Tag: devFrExtDlciTxFrOutCIR

(1 min)

 

configured.

 

 

 

 

 

 

 

 

 

OID: .1.3.6.1.4.1.1795.2.24.2.

 

 

 

 

 

 

6.9.4.1.1.17.I.D

 

 

 

 

 

 

 

 

 

 

 

Tx CIR Utilization

D

MIB: FR DTE MIB

60 secs

None

Must be

0

 

 

(RFC 2115)

(1 min)

 

configured.

 

 

 

Tag: frCircuitSentOctets

 

 

 

 

 

 

OID: .1.3.6.1.2.1.10.32.2.1.

 

 

 

 

 

 

7.I.D

 

 

 

 

 

 

 

 

 

 

 

1 D = Delta. Indicates that the calculated difference between the current value and the previous value is contained in the MIB.

A = Absolute. Indicates that the exact value for the item is contained in the MIB.

2 I in the OID = Interface ID of the frame relay link. D = DLCI number.

Table B-13.

Dynamic DLCI Alarm Defaults ± NetScout Area

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rising

Falling

 

 

Sample

MIB/Tag/OID 2

 

Event

Threshold

Threshold

Item

 

Type 1

Interval

Type

Default

Default

Rx DLCI Link

 

D

MIB: FR DTE MIB

60 secs.

Rising

70% of link

65% of link

Utilization

 

 

(RFC 2115)

(1 min)

 

capability

capability

 

 

 

Tag: frCircuitReceivedOctets

 

 

 

 

 

 

 

OID: .1.3.6.1.2.1.10.32.2.1.

 

 

 

 

 

 

 

9.I.D

 

 

 

 

 

 

 

 

 

 

 

 

Tx DLCI Link

 

D

MIB: FR DTE MIB

60 secs.

Rising

70% of link

65% of link

Utilization

 

 

(RFC 2115)

(1 min)

 

capability

capability

 

 

 

Tag: frCircuitSentOctets

 

 

 

 

 

 

 

OID: .1.3.6.1.2.1.10.32.2.1.

 

 

 

 

 

 

 

7.I.D

 

 

 

 

 

 

 

 

 

 

 

 

1 D = Delta. Indicates that the calculated difference between the current value and the previous value is contained in the MIB.

A = Absolute. Indicates that the exact value for the item is contained in the MIB.

2 I in the OID = Interface ID of the frame relay link. D = DLCI number.

9123-A2-GB20-00

May 2000

B-21

Page 239
Image 239
Paradyne 9123 manual Rx Dlci Link