Troubleshooting

Table 6-1. Alarm Conditions (2 of 4)

Alarm Condition

What It Indicates

What To Do

 

 

 

Ethernet Link Down

The communication link for

Check the LAN connected to the

 

the Ethernet port is down

Ethernet port.

 

and the Interface Status for

 

 

the port is enabled.

 

 

 

 

Link Down

The specified frame relay

Verify that the network LMI is up.

Administratively,

link has been disabled by

If it is, contact your network

frame relay link 2

the unit due to LMI

provider.

 

Behavior conditions or LMI

 

 

Protocol on another link is

 

 

in a failed state.

 

 

This is not an alarm

 

 

condition so System

 

 

Operational appears,

 

 

as well.

 

 

 

 

LMI Down,

The Local Management

For the network interface:

frame relay link 2

Interface is down for the

H If LMI was never up, verify

 

specified frame relay link.

 

that the LMI Protocol setting

 

 

 

 

reflects the LMI type being

 

 

used.

 

 

H If LMI was never up:

 

 

± Verify that the proper time

 

 

slots have been configured.

 

 

± Verify that the LMI Protocol

 

 

setting reflects the LMI type

 

 

being used.

 

 

H Verify that Frame Relay

 

 

Performance Statistics show

 

 

LMI frames being transmitted.

 

 

If all of the above have been

 

 

verified and the physical link is

 

 

not in Alarm, contact your

 

 

network provider.

 

 

 

2 frame relay link is one of the following:

± Net1-FR1. The frame relay link specified for the network port, Network 1.

± Port-1. The frame relay link associated with the user data port.

6-8

May 2000

9123-A2-GB20-00

Page 158
Image 158
Paradyne 9123 manual Alarm Conditions 2 What It Indicates What To Do, Operational appears