Configuration

Configuring PVC Connections

The Auto-Configuration feature automatically configures PVC Connections and their DLCI Records. PVC Connections can also be created manually (see Table 3-8).

Main Menu Configuration PVC Connections

From this screen, you can go directly to the Management PVC screen by selecting the MgmtPVCs function key for easy movement between screens.

Quick removal of unused DLCIs included in an existing PVC Connection, except for HQ_Site, is also available when the Del ete function key is selected and you respond Yes to the Remove otherwise unused components associated

with the deleted PVC? prompt.

To configure these options, Service Type on the Easy Install screen must be set to Frame Relay.

Table 3-8. PVC Connection Options (1 of 2)

Source Link

Possible Settings: Port-1,Net1-FR1

Default Setting: Initially blank; no default.

Specifies the frame relay interface that starts a PVC connection; the from end of a from-to link. The only valid settings for this configuration option are frame relay interfaces that have at least one DLCI or EDLCI defined that are not part of a PVC connection or management link. For example, if Port-1 has no DLCIs defined, Port-1 would not appear as a valid setting.

Port-1± Specifies the user data port as the source link.

Net1-FR1± Specifies the Network interface or network data port as the source link.

Clear All ± Clears all Link and DLCI settings, and suppresses EDLCIs.

Source DLCI

Possible Settings: 16 ± 1007

Default Setting: Initially blank; no default.

Specifies the source DLCI for a frame relay interface. The DLCI must be defined and cannot be part of a PVC connection or management link. For multiplexed DLCIs, at least one EDLCI must be unconnected for the DLCI to be a valid selection.

NOTE: Source DLCI has no value if Source Link contains no value.

16 ± 1007 ± Specifies the DLCI number.

Source EDLCI

Possible Settings: 0 ± 62

Default Setting: Initially blank; no default.

Specifies the source Embedded Data Link Connection Identifier (EDLCI) for a frame relay interface when a multiplexed DLCI record is selected as one end of a connection.

Display Conditions ± This option only appears when Source DLCI contains a multiplexed DLCI record number.

0 ± 62 ± Specifies the EDLCI number.

3-40

May 2000

9123-A2-GB20-00

Page 72
Image 72
Paradyne 9123 manual Configuring PVC Connections, Main Menu → Configuration → PVC Connections, PVC Connection Options 1