Operation and Maintenance

Test Status Messages

These test messages appear in the right column of the System and Test Status screen. You have the option of allowing the test to continue or aborting the test. See Chapter 6, Troubleshooting, for more information on tests, including how to start and stop them.

Table 5-8. Test Status Messages (1 of 2)

Message

What It Indicates

DCLB Active, [Net1-FR1/Port-1]

A Data Channel V.54 Loopback (DCLB) is active

 

 

on the T1 network frame relay link, or on the data

 

 

for the user data port.

 

 

DTE External LB Active, Port-1

An external DTE Loopback is running on the user

 

 

data port.

 

 

DTE Init. Ext LB Active, Port-1

The DTE has initiated an external DTE Loopback

 

 

on the user data port.

 

 

DTPLB Active, Port-1

A Data Terminal Payload Loopback (DTPLB) is

 

 

active for the specified slot and port.

 

 

Lamp Test Active

The Lamp Test is active, causing the LEDs on the

 

 

faceplate to flash on and off.

 

 

LLB Active, Network 1

A network Line Loopback (LLB) is active on the

 

 

specified interface.

 

 

Monitor Pttn Active, DLCI nnnn,

The unit is monitoring a test pattern on the

frame_relay_link 1, 2

specified DLCI on the specified frame relay link.

Monitor Pttn Active, [Interface]

A Monitor Pattern test is active on the specified

 

 

interface.

 

 

This test cannot be activated on user data ports

 

 

that have Port Use set to Frame Relay.

 

 

No Test Active

No tests are currently running.

 

 

PLB Active, Network 1

A Payload Loopback (PLB) is active on the

 

 

specified interface.

 

 

PVC Loopback Active, DLCI nnnn,

A PVC Loopback is active on the specified DLCI

frame_relay_link 1, 2

on the frame relay link.

RLB Active, Network 1

A network Repeater Loopback (RLB) is active on

 

 

the specified interface.

 

 

 

1

nnnn indicates a DLCI number of 16 through 1007.

2

frame relay link is one of the following:

 

± Net1-FR1. The frame relay link specified for the network interface, Network 1.

 

± Port-1. The frame relay link associated with the user data port.

 

 

 

9123-A2-GB20-00

May 2000

5-17

Page 123
Image 123
Paradyne 9123 manual Test Status Messages 1 What It Indicates