MODEL PS-2100MA:
Two switches permit Battery Type and Charge Rate selection.
Switch #1 permits selection of either regular battery in automatic operation or Deep- cycle battery in automatic operation. If you are not sure of your battery type, use the regular battery setting.
Switch #2 (4 Charge Rate Modes)
Mode 1– Select 15 Amp, 6 Volt Manual Operation to charge medium and large size
Manual Operation. Monitor frequently while charging a battery. Not doing so may cause damage to your battery or result in other property damage or personal injury.
Mode 2 – Select the 2 Amp automatic setting to charge small 12 Volt batteries (31 Ah or less) or to warm larger
Mode 3 – Select 15 Amp automatic for larger 12 Volt batteries for a faster charge. Mode 4 – Select 100 Amp Engine Start to assist in engine cranking of 12 Volt systems.
DO NOT use on 6 Volt systems. Use the 100 Amp Engine Start position for cranking automobiles or light trucks.
NOTE: Use only with battery in the vehicle. This will reduce the chance of damaging sensitive electronic equipment in the vehicle.
(SWITCH #1) |
| (SWITCH #2) |
| ||
BATTERY TYPE SELECTOR | CHARGE RATE SELECTOR | ||||
CONVENTIONAL | MAINTENANCE- | 15 A, 6 V | 2 A | 15 A | 100 A, 12 V |
AND LOW | FREE AND | MANUAL | 12 V AUTOMATIC | ENGINE START | |
MAINTENANCE |
|
|
|
|
11.READING METERS PS-1022MA
0 2 4 6 8 10 12
0 2 4 6 8 10 12
0 2 4 6 8 10 12
FULLY DISCHARGED BATTERY
Initial charge current to the battery is typically 10 Amp. The needle points toward the 25% mark.
APPROACHES FULL CHARGE
Charge current to the battery is typically 5 Amp. The needle points toward the 100% mark.
FULLY CHARGED BATTERY
Charge current to the battery is 0 Amp, and the Full Chargegreen LED glows. The needle points toward the Full Charge LED. (Automatic Position)
• 7 •