15.STORAGE INSTRUCTIONS
15.1Store the charger unplugged, in an upright position. The cord will still conduct electricity until it is unplugged from the outlet.
15.2Store inside, in a cool, dry place (unless you’re using an
15.3Do not store the clips on the handle, clipped together, on or around metal, or clipped to cables.
16.TROUBLESHOOTING
PROBLEM | POSSIBLE CAUSE | REASON/SOLUTION |
|
|
|
No meter reading. | Connections are reversed. | With charger unplugged, reverse |
|
| clamps and reconnect. (Rock |
|
| clamps back and forth to ensure |
|
| clamps are connected.) |
| Poor electrical connection. | Clean clamps and battery posts |
|
| and reconnect. (Rock clamps |
|
| back and forth to ensure clamps |
|
| are connected.) |
| AC outlet is dead. | Plug in a lamp or other appliance |
|
| to check for voltage. |
| Battery is defective (will not | Have battery checked. |
| accept charge). |
|
Charger will not turn | Battery recently charged as | Battery does not need charging. |
on (when properly | result of driving and is fully | (Turning on headlights will lower |
connected to power) in | charged. | battery voltage in a few seconds |
automatic mode only. |
| and charger should then turn on.) |
|
|
|
Charger will not turn | Battery has problem and will not | Have battery checked. |
OFF. | take full charge, or it is a manual |
|
| charger. |
|
Meter needle | Battery has reached Full Charge | Have battery checked. |
fluctuates back and | and and is not able to maintain |
|
forth from the middle | above 13V. |
|
to the left. |
|
|
Meter needle pulses | Two or more batteries connected | Do not parallel charge. |
(fluctuates) every | in parallel. |
|
few seconds AFTER | Battery of 200 ampere hours or | Requires more time to charge: |
THREE HOURS | ||
without slowing down. | larger. | continue charging. |
| Battery is connected to a device | Use larger device. |
| that draws a small current (such |
|
| as an interior light). |
|
Meter needle moves | Battery is severely discharged | Allow charging to continue until |
to extreme right, | (but otherwise good). | battery has recovered sufficiently |
remains a short time, |
| to take a charge. (Circuit breaker |
then returns to zero, |
| will continue to cycle and needle |
accompanied by a |
| will swing side to side until battery |
clicking sound. |
| has recovered.) |
| Battery is defective (will not | Have battery checked. |
| accept charge). |
|
| Charger is cycling after circuit | Wait until charger automatically |
| breaker overload. | resets itself. |
• 10 •