9.TROUBLESHOOTING

 

PROBLEM

REASON

SOLUTION

 

 

 

 

 

Red LED is on,

Poor contact at

Unplug and reinsert the 12V

 

audible alarm

terminals.

plug or check connections at

 

is on, and/or

 

power supply.

 

converter does

Fuse blown.

See “IF THE Converter

 

not function.

 

 

 

FUSE BLOWS” section.

 

 

Converter

See “LED INDICATOR

 

 

shutdown.

AND SHUTDOWN

 

 

 

PROTECTION” section.

 

 

Converter may

See Warranty and contact

 

 

not be working

Customer Service.

 

 

properly.

 

 

 

 

 

 

 

 

 

 

10. SPECIFICATIONS

 

 

Maximum Continuous Power

410 Watts

 

Surge Capability (Peak Power)

820 Watts

 

No Load Current Draw

<0.5A

 

Wave Form

 

Modified Sine Wave

 

Input Voltage Range

10.5V-15.5V DC

 

Output Voltage Range

120V ± 5% AC

 

Low Battery Alarm

Audible, 11V ± 0.3V DC

 

Low Battery Shutdown

10.5V ± .3V DC

 

High Battery Shutdown

15.5V ± 0.5V DC

 

Optimum Efficiency

85%

 

AC Outlet

 

Two, NEMA 5-15 USA

 

USB Port

 

One, 5V DC 2.1A

 

Fuse

 

Two, 25A (Spade Type)

 

Dimensions

 

6.5" L x 4.13" W x 2.2" H

 

Weight

 

approximately 2 lbs.

• 10 •

Page 10
Image 10
Schumacher X141B owner manual Troubleshooting Problem Reason Solution, Specifications